Section Cut From The Countertop - Smeg SIB2741D Manual

Table of Contents

Advertisement

3. Reconnect the appliance to the mains power
supply.
Carry out the following procedure within 30
seconds of the appliance being reconnected:
4. Press and hold the
controls.
5. Press the
and
time.
• A beep will be emitted and the current
power level will be shown on the display.
6. Use the
and
value.
7. Press the
and
time to save the new power value. The
appliance will switch off and you will have
to switch it on again in order to use it with the
new power limits.
• If you do not wish to save the changes,
simply do not use the display for at least 60
seconds.
The following procedure can be used to adjust
the maximum power from 2.8 to 1.0 kW (low
power regime):
1. Follow the instructions described above as far
as point 4.
2. Press the
and
time.
• A beep will be emitted and the current
power level will be shown on the display.
3. Use the
and
value.
4. Press the
and
time to save the new power value. The
appliance will switch off and you will have
to switch it on again in order to use it with the
new power limits.
• If you do not wish to save the changes,
simply do not use the display for at least 60
seconds.

Section cut from the countertop

Safety instructions for positioning and
installation
See General safety instructions.
• Installation can be carried out on various
materials such as masonry, metal, solid
wood or plastic laminated wood as long as
32 - INSTALLATION
button to unlock the
buttons at the same
buttons to change the
buttons at the same
buttons at the same
buttons to change the
buttons at the same
they are heat resistant (>90°C).
• Veneers, adhesives or plastic coatings on
adjacent furniture should be temperature-
resistant (>90°C), otherwise they might
warp over time.
• If the piece of furniture does not have the
required recess opening, either it will have
to be cut or masonry work carried out by a
competent technician.
• The minimum clearance between exhaust
hoods and the cooking surface must be at
least the distance indicated in the exhaust
hood installation instructions.
• The minimum clearances must also be
respected for the edges of the hob on the
back as indicated in the assembly
instructions.
• If the appliance is to be installed above an
oven, the oven must be fitted with a cooling
fan.
Appliance overall dimensions (mm)
MODELS (cm)
60
70
Built-in cabinet dimensions (mm)
A min. 150
B min. 460
C min. 750
D 30 - 50
E min. 50
L min. 600-700
L
600
750
91477A677/A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sib2641d

Table of Contents