E.10 Replacing the adjustment spring of the
pressure regulator (Only for Australia)
To replace the spring "D" of the pressure regulator with one
suitable for the gas pressure type indicated in table "B" (see
Appendix) proceed as follows:
1. Remove the seal cap "A", the seal cap gasket "B", the
adjusting screw "C" and the spring "D" (see image);
2. Insert the new spring (blue colour = propane gas; silver
colour = natural gas) and replace the adjusting screw;
3. Connect a pressure gauge to the appliance's test point
pressure – (see paragraph E.8.1 Supply pressure check-
ing (all versions));
4. Ignite the appliance's burners so to have the maximum
gas consumption;
5. Regulate the adjustment screw until the pressure gauge
shows the working pressure value (see paragraph E.7.5
Gas pressure regulator);
6. Replace the seal cap and gasket and screw tightly closed;
7. Remove the pressure gauge and close the test point
pressure;
8. Prior to operation, test the gas pressure regulator for leaks.
B
D
E.11

Electrical connection

WARNING
Work on the electrical systems
must only be carried out by
specialised personnel.
Before connecting, make sure that:
1. the mains voltage and frequency match those indicated on
the appliance data plate;
2. there is an efficient earth contact;
3. the power supply must be carried out in compliance with
the regulations and provisions in force in the country of
use;
4. a differential thermal-magnetic switch suitable for the input
specified on the dataplate, with contact gap enabling
complete disconnection in category III overvoltage con-
ditions and complying with the regulations in force, is
installed between the power cable and the electric line;
For the correct size of the switch, refer to the absorbed
current specified on the appliance dataplate.
18
A
C

E.11.1 Electrical appliances

To access the terminal block:
1. Undo and remove the fixing screws from the bottom of the
front panel;
2. remove the front panel of the appliance (see Fig. 5);
3. connect the power cable to the terminal block "M" accord-
ing to the wiring diagram provided with the appliance;
4. secure the power cable with the cable clamp;
5. after making the connection, with the machine working
check that the power supply does not fluctuate by ±10%
the rated voltage;
6. installation requires the inclusion of a device lockable in
the "open" position during maintenance.
IMPORTANT
The manufacturer declines any liability if the safety
regulations are not respected.

E.12 Power cable

Unless otherwise specified, our appliances are not equipped
with a power cable.
The installer must use a flexible cable having characteristics
not lower than the H07RN-F rubber insulated type.
Protect the section of cable outside the appliance with a metal
or rigid plastic tube.
WARNING
If the power cable is damaged, it
must be replaced by the after-
sales service or in any case by
qualified personnel, in order pre-
vent any risk
WARNING
The manufacturer declines any
liability for damage or injury
resulting from breach of the
above rules or non-compliance
with the electric safety regulation
in force in the country where the
machine is used

E.13 Circuit breaker

Verify that a safety circuit breaker is installed between the
power cable of the appliance and the mains electric line.
Fig. 5