Table A–8. Sarasota PD900spares
P/N
SFD****
HD-B0070
H90-0030/A
16-319/B
ZR20-0127/B
ZR40-5870/B
ZW10-08-030/B
ZR20-0117/B
ZF12-0051/B
PC251/252-T
Local display
Table A–9. Sarasota PD900 installation accessories
P/N
PD70-2693B
PD70-4076
ZB/MTL/D1
ZB/MTL/D2
ZB/MTL/D3
ZB/MTL/D4
ISO/P+F/GH
Thermo Fisher Scientific
Description
Spare sensing spool (consult Thermo Fisher)
Spool lock ring
Preset torque wrench
Heat transfer fluid, 50 ml bottle
End cap O-ring, packet of 5
Body/pocket O-ring, packet of 5
Fixing screws, M8 x 30 stainless steel, packet of 6
Box seal ring, packet of 2
Filter element for coalescing filter, packet of 10
HME spare card set. Includes PC251 processor and PC252 safety and isolation PCBs
Local display kit for Sarasota HME900. Includes mounting components and display PCB
Description
Standard pocket, carbon steel A350-LF2. Pressure rating up to 150 bar.
Standard pocket, 316L SS. Pressure rating up to 100 bar.
For use with smart headmounted electronics option with pressure transducer input (set of 3 barriers):
2x MTL7728/28V-300 ohm for density meter power supply and pressure transducer loop power
1x MTL7787S/28V-300 ohm + diode return to power HART signal loop 4–20 mA
For use with frequency output option with connection to Sarasota CM515 (set of 3 barriers):
1x MTL7787S/28V-300 ohm + diode return to power density meter
2x MTL7755 dual channel 3V-10 ohm AC barriers
For use with smart headmounted electronics option without pressure transducer input (set of 2 barriers):
1x MTL7728/28V-300 ohm for density meter power supply
1x MTL7787S/28V-300 ohm + diode return to power HART signal loop 4–20 mA
For use with frequency output option with connection to Sarasota CM515 with pressure transmitter input
(set of 4 barriers):
2x MTL7787S/28V-30 ohm + diode return for power to density meter and pressure transducer
2x MTL7755/3V 10 ohm AC barriers for PT 100, extra barrier allows for pressure input
Isolation barriers for use with smart headmounted electronics option without pressure transducer input
(set of 2 barriers):
1x KFD2-STC3-Ex1 for HART signal loop 4–20 mA
1x KFD2-SD-Ex1.48 for density meter power; should be used when no earth ground is available or in
some countries or locations when the device is used in Zone 0 hazardous area
User Guide for Sarasota ID900, FD900, & PD900 Gas Density Meters
Ordering Information
Sarasota PD900
A-7