Electrical Specification - TECPEL DCM-043 Instruction Manual

Mini ac/dc clamp meter
Table of Contents

Advertisement

Electrical Specification:

( Ⅰ ) The accuracy specification is defined as ± ( ...%reading
+ ...count ) At 23 ± 5 ℃ , ≦ 80 %RH
ACA (Autorange)
Range
Resolution
10A
1mA
80A
10mA
80~100A
10mA
Accuracies are specified from 5% to 100% of range
DCA (Autorange)
Range
Resolution
10A
1mA
80A
10mA
80~100A
10mA
Accuracies are specified from 5% to 100% of range
ACV
Range Resolution
600V
0.1V
DCV
Range Resolution
600V
0.1V
Ohm ( Ω )
Range
Resolution
10K Ω
1 Ω
Continuity (
Range
Active Region
<100 Ohm
(Ⅱ) Analog output: ( for ACA & DCA range)
10 mV/Amp (20KHz at ± 3dB)
Accuracy: ± (4.5% reading + 0.5mV)
Output impedance: approx 3KΩ
Overload protection: 600 Vrms
Accuracy ( 50Hz~500Hz)
2%+10
3.5%+10
Accuracy
2.5%+10
4.5%+10
Accuracy (50Hz~500Hz)
1.5%+5
Accuracy
1%+2
Accuracy
MAX Test Voltage Overload Protection
1%+3
3V
)
MAX Test Voltage
3V
DC
3
Instruction Manual
Overload Protection
150Arms
Overload Protection
150Arms
Overload Protection
660Vrms
Overload Protection
660Vrms
600Vrms
DC
Overload Protection
600Vrms

Advertisement

Table of Contents
loading

Table of Contents