II. Specification

General Specification:

Digital Display:
4 digits LCD display with maximum reading 9999
Over Load:
OL
When the signal input exceeds the maximum limit "
" will
be display.
Sample Rate:
2 times/sec
Peak Hold Sample Rate:
10ms at DCV, DCA
Low Power Indication:
When the battery is below the proper operation range,
symbol will appear on the LCD display.
Auto Power Off:
The meter will power it self OFF after 30 minutes of
inactivity.
Electromagnetic Compatibility:
Vac and Aac only: RF field = 3V/m
Total accuracy = specified accuracy + 5.0% of range
Power Source: UM-4 or AAA 1.5V battery x 2.
Battery Life: 45 hr approx. (alkaline battery)
Clamp opening size: 12.5mm(1/2 inch)
Dimension (L x W x H) :
202x70x34mm, 7.95x2.76x1.33 inch
Weight: 180g( include battery)
Accessory:
Instruction Manual, Carrying Case, Test lead, Battery
1.5Vx2