Setting The Temperature - Prince Castle EHB-CE Series Operation Manual

Extended hold bin
Table of Contents

Advertisement

Extended Hold Bin
EHB-CE Series
The unit has multiple shelves, each with an upper and lower heater for each zone.
The heaters follow the default setpoints of the preset products for each pan
Each heater has a programmable range of 150° – 275°F (66° – 135°C).
Use the instructions below and the following steps to set the setpoint temperatures for each heater.
NOTE: Only applicable in stand-alone mode when not connected to Product Management sys-
tem, setpoint cannot be changed when connected to a kitchen manager.
This LED will be lit to indicate upper shelf is selected.
This LED will be lit to indicate unit is in Program Mode.
This LED will be lit to indicate lower shelf is selected.
ACTUAL TEMP BUTTON and LED
Press to display actual temperature for the
selected heater. LED will be lit when actual
temperature is displayed.
SETPOINT BUTTON and LED
Press to display setpoint temperature of a
selected heater. LED will be lit when setpoint
temperature is displayed.
1
The SET PRODUCT TEMP menu is used to change the Hold and Cook-More times.
Press and hold the PRINCE CASTLE LOGO button, then immediately press and hold the ENTER button until the display shows one of six
programming menus.....(hold for about 5 seconds)
Use the UP or DOWN Arrow button to scroll to the PROD BURG ↑ ↓ ENTR (Set Product Temperature) menu.
2
Press the ENTER button to enter the programming menu, the display should then read SEL TEMP XXXX ↑ ↓
XXXX is where the product abbreviation is displayed. Use the UP and DOWN arrows to navigate to the desired product.
3
Press the ENTER button to select that product profile to update, the display will read SET UPR XXXX ###s↑ ↓
the product abbreviation is displayed, and ### is the temperature. Use the UP and DOWN arrows to set the temperature of the
upper heater of that zone.
Printed in USA 05/19 © 2019
Setting the Temperature (Standalone Mode)
UPPER SHELF LED
PROG LED
LOWER SHELF LED
DISPLAYED TEMPERATURES
ARE HEATER TEMPERATURES
AND DO NOT INDICATE ACTUAL
CAUTION:
FOOD TEMPERATURES.
Confirm setpoint by pressing ENTER
8
TEMPERATURE DISPLAY
A, B, C, D ( E, F ) = ZONES
Upper and Lower Heater
UP/DOWN ARROW BUTTONS
Used with other Buttons to scroll through heater
and temperature selections.
PRINCE CASTLE LOGO BUTTON
Press to enter temperature selections.
NOTE: To reset all calibrations to the factory set-
tings, turn the unit off, then press and hold the UP and
DOWN Arrow buttons simultaneously while turning the
unit back on. A "P" will appear in the display and all
calibrations will be reset to original factory settings.
the
the XXXX is where
540-541revJ-EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehb22aceEhb23aceEhb32aceEhb24aceEhb42aceEhb34ace

Table of Contents