Setting The Temperature - Prince Castle EHB Series Operation Manual

Dedicated holding bin
Hide thumbs Also See for EHB Series:
Table of Contents

Advertisement

The unit has multiple shelves, each with an upper and lower heater for each zone.
The heaters follow the default set points of the preset products for each pan
Use the instructions below and the following steps to set the set point temperatures for each heater.
This LED will be lit to indicate upper shelf is selected.
This LED will be lit to indicate unit is in Program Mode.
This LED will be lit to indicate lower shelf is selected.
ACTUAL TEMP BUTTON and LED
Press to display actual temperature for the
selected heater. LED will be lit when actual
temperature is displayed.
SETPOINT BUTTON and LED
Press to display set point temperature of a
selected heater. LED will be lit when set point
temperature is displayed.
1
The SET PRODUCT TEMP menu is used to change the Hold and Cook-More times.
Press and hold the PRINCE CASTLE LOGO button, then immediately press and hold the ENTER button until the display shows one of six
programming menus.....(hold for about 5 seconds)
Use the UP or DOWN Arrow button to scroll to the PROD BURG ↑ ↓ ENTR (Set Product Temperature) menu.
2
Press the ENTER button to enter the programming menu, the display should then read SEL TEMP XXXX ↑ ↓ . The XXXX is where the
product abbreviation is displayed. Use the black UP and DOWN arrows to navigate to the desired product.
3
Press the ENTER button to select that product profile to update, the display will read SET UPR XXXX ###s↑ ↓
the product abbreviation is displayed, and ### is the temperature. Use the UP and DOWN arrows to set the temperature of the
upper heater of that zone.
540-539-EN

Setting the Temperature

UPPER SHELF LED
PROG LED
LOWER SHELF LED
DISPLAYED TEMPERATURES
ARE HEATER TEMPERATURES
AND DO NOT INDICATE ACTUAL
CAUTION:
FOOD TEMPERATURES.
Confirm set point by pressing ENTER
7
Dedicated Holding Bin
EHB Series
TEMPERATURE DISPLAY
A, B, C, D ( E, F ) = ZONES
Upper and Lower Heater
UP/DOWN ARROW BUTTONS
Used with other Buttons to scroll through heater
and temperature selections.
PRINCE CASTLE LOGO BUTTON
Press to enter temperature selections.
NOTE: To reset all calibrations to the factory set-
tings, turn the unit off, then press and hold the UP and
DOWN Arrow buttons simultaneously while turning the
unit back on. A "P" will appear in the display and all
calibrations will be reset to original factory settings.
the XXXX is where
Printed in USA 12/16 © 2016