Download Print this page

ABB DCS800 Series Quick Manual page 20

Hide thumbs Also See for DCS800 Series:

Advertisement

DCS800 Control Panel
The following table summarizes the button functions and displays of the
DCS800 Control Panel (DCS CP).
With USISel (16.09) it is possible to limit the amount of displayed parameters!
General display features
Following modes are available in the MAIN MENU:
1.
Parameters mode
.
Start-up assistants mode
a.
Name plate data
b.
Macro assistant
c.
Autotuning field current controller
d.
Autotuning armature current controller
e.
Speed feedback assistant
(Tacho fine tuning not available)
f.
Autotuning speed controller
g.
Field weakening assistant
(only used when maximum speed is higher than
base speed)
3.
Macros mode (currently not used)
4.
Changed parameters mode (compare to default and
display changed parameters)
5.
Fault logger mode (Display fault history)
6.
Clock set mode
7.
Parameter backup mode
• copy active parameter set from the drive into the
DCS800 Control Panel (only in local mode)
• copy parameter set from DCS800 Control Panel into
the drive (only in local mode)
8.
I/O settings mode (currently not used)
0
3ADW000191R0500 DCS800 Quick guide edisf e
Parameters entered by assistant
99.0
Motor 1 nominal Voltage
99.03
Motor 1 nominal current
99.04
Motor 1 base speed
0.01
Motor 1 minimum speed
0.0
Motor 1 maximum speed
99.11
Motor 1 nominal field current
30.09
Armature over current level
30.16
Motor 1 over speed
99.10
Nominal mains voltage
99.1
Motor 1 used fex type
0.05
Torque maximum
0.06
Torque minimum
0.1
Motor 1 current limit bridge 1
0.13
Motor 1 current limit bridge 
50.04
Motor 1 encoder pulse number, if selected
50.0
Motor 1 encoder measured mode, if selected
50.13
Motor 1 tacho volt, only DWL
50.1
Motor 1 tacho adapt, only DWL
0.03
Zero speed limit
.01
Acceleration time 1
.0
Deceleration time 1
30.1
Motor 1 field minimum trip
44.01
Field control mode
DCS800 QG pan ov_a.dsf

Advertisement