Mitsubishi MELSEC-A AJ65VBTCU-68DAVN User Manual page 85

Digital-analog converter module
Table of Contents

Advertisement

5 PROGRAMMING
PLC CPU
Ver. 1 compatible For write
W100
W101
W102
W103
W104
W105
W106
W107
W108
W109
W10A
W10B
Ver. 1 compatible For read
W000
W001
W002
W003
W004
W005
W006
W007
W008
W009
W00A
W00B
Ver. 2 compatible For write
W1500
W1501
W1502
W1503
W1504
W1505
W1506
W1507
W1508
W1509
W150A
W150B
W150C
W150D
W150E
W150F
Ver. 2 compatible For read
W1000
W1001
W1002
W1003
W1004
W1005
W1006
W1007
W1008
W1009
W100A
W100B
W100C
W100D
W100E
W100F
5 - 23
[Remote registers (RWw, RWr)]
Remote device station (Station number 1)
RWw0 (A/D conversion enable/prohibit specification)
RWw1 (CH. 1 to CH. 4 input range setting)
RWw2 (CH. 5 to CH. 8 input range setting)
RWw3 (Average processing specification)
RWw4 (CH. 1 average time, number of times setting)
RWw5 (CH. 2 average time, number of times setting)
RWw6 (CH. 3 average time, number of times setting)
RWw7 (CH. 4 average time, number of times setting)
RWw8 (CH. 5 average time, number of times setting)
RWw9 (CH. 6 average time, number of times setting)
RWwA (CH. 7 average time, number of times setting)
RWwB (CH. 8 average time, number of times setting)
RWr0 (CH. 1 digital output value)
RWr1 (CH. 2 digital output value)
RWr2 (CH. 3 digital output value)
RWr3 (CH. 4 digital output value)
RWr4 (CH. 5 digital output value)
RWr5 (CH. 6 digital output value)
RWr6 (CH. 7 digital output value)
RWr7 (CH. 8 digital output value)
RWr8 (Error code)
RWr9 (Reserved)
RWrA (Reserved)
RWrB (Reserved)
AJ65VBTCU-68ADV
MELSEC-A
Remote device station (Station number 4)
AJ65VBTCU-68DAVN
RWw0 (CH. 1 digital value setting)
RWw1 (CH. 2 digital value setting)
RWw2 (CH. 3 digital value setting)
RWw3 (CH. 4 digital value setting)
RWw4 (CH. 5 digital value setting)
RWw5 (CH. 6 digital value setting)
RWw6 (CH. 7 digital value setting)
RWw7 (CH. 8 digital value setting)
RWw8 (Analog output enable/prohibit setting)
RWw9 (CH. 1 to CH. 4 output range setting)
RWwA (CH. 5 to CH. 8 output range setting)
RWwB (HOLD/CLEAR setting)
RWwC (Reserved)
RWwD (Reserved)
RWwE (Reserved)
RWwF (Reserved)
RWr0 (CH. 1 check code)
RWr1 (CH. 2 check code)
RWr2 (CH. 3 check code)
RWr3 (CH. 4 check code)
RWr4 (CH. 5 check code)
RWr5 (CH. 6 check code)
RWr6 (CH. 7 check code)
RWr7 (CH. 8 check code)
RWr8 (Error code)
RWr9 (Reserved)
RWrA (Reserved)
RWrB (Reserved)
RWrC (Reserved)
RWrD (Reserved)
RWrE (Reserved)
RWrF (Reserved)