5.10.2 RS232-RS485/422 interface
These interfaces are physically connected through the 5-pin and 4-pin terminal block con-
nectors. The insulation strength is up to 2.5 kV. Attention, connectors are not isolated from
each other! No state indication is displayed for this interface. These router versions comply
with the standards and temperature ranges stated in Chap. 7.1.
Figure 41: Version with RS232-RS485/422 interface
When connecting counterpart terminal block connectors (included in package with the router),
use cables with nominal cross section 0.2 to 1.0 square mm (30 to 16 AWG). Recommended
stripping length is 5 mm. For M2 captive screws the screw driver 0.5 x 3 mm is recommended.
Tighten the screws with 0.3 Nm torque.
Connection of RS232 connector:
Pin
Signal
1
CTS
2
RTS
3
GND
4
RXD
5
TXD
Both connectors (RS232 and RS485/422) have a common ground connection.
Description
Clear To Send
Request To Send
Signal ground
Receive Data
Transmit Data
Table 20: Connection of RS232 connector
Figure 42: RS232 connector
35
SmartFlex SR305
Direction
Output
Input
—
Input
Output