4. Pneumatic components (when the pneumatic center guide is used)

WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the
following work after turning the power off and ascertaining that the motor is at rest.
1
Decrease
2
Increase
A
– 4 –
(1) Installing the regulator
Install regulator (asm.) ❶ on mounting plate ❺
1)
with screw ❷ , spring washer ❸ and nut ❹ which
are supplied with the unit.
Attach joint ❻ to inlet 1 . Attach joint ❼ to outlet
2)
2 .
Attach mounting plate ❺ on the undersurface of
3)
the table with accessory screws ❽ supplied with
the plate.
6 air tube to joint ❼ .
4)
Connect the
ø
Screw ❷ which is supplied with the unit:
*
Thread diameter M5; Length: 12 mm
(SM6051202TP)
(2) Adjusting the air pressure
1)
The operating air pressure is 0.5 to 0.55 MPa.
Adjust the air pressure using air pressure regulat-
ing knob ❶ of the filter regulator.
In the case fluid accumulation is observed in A
2)
section of the filter regulator, turn drain cock ❷ to
drain the fluid.