Product Care Information

Battery Charge

• You can charge the battery by plugging the USB cable into any
of the power supplies listed below:
• A computer
• A USB wall-charger with an output of 5 volts and 1 amp
• A DC car-charger with an output of 5 volts and 1 amp
• It takes about 1-2 hours to fully charge the battery from
empty. Try not to let the battery completely run out before
charging. Charge as needed.
• To check remaining battery level, see below for Battery Level
Indicator.

Battery Level Indicator

When powering off
• When powering off the scale, the Battery Level Indicator can be seen on the top of the display.
• You can also check the battery level in the main settings menu. When the scale is powered
off, press and hold the Power button, the LED display will show [ ACAIA ] and then changes
to [ SEt ]. Continue holding the Power button until the battery percentage is displayed.
• You can also check the battery level by connecting the scale to Acaia Apps.

Calibration

Turn on scale
Turn on the Acaia
scale.
Note: You may also use 500 g, 1000 g or 2000 g weights. If you use weights other than Acaia
Weights, we recommend F2 class standard calibration weights.

Care and Cleaning

• Use a soft cloth with warm water only to clean the product.
• Do not use detergent or other chemicals for cleaning and soaking as it can damage the
anodized coating on the product.
Tap T button
Make sure the scale
is in weighing mode
and the unit is set to
'gram', then tap the
'T' button rapidly.
When accessing settings
See CAL display
Keep tapping the 'T'
button until 'CAL' is
shown on the
display.
Place a weight
Place a weight on the
scale and wait until the
display shows '_End_'.
Calibration is now
complete!