Weighing Resolution Setting [ rESoL ]
1. The Weighing Resolution is automatically set to [ dEFAUL ]: the division is 0.1 g/0.002 oz.
2. Tap the Tare button to switch the Weighing Resolution between [ dEFAUL ] and [ hiGh ].
3. When the Weighing Resolution is set to high, the division will be 0.01 g/0.0005 oz. The default
display will show [ 0.00 ] when the scale is set to grams, and [ 0.0000 ] for ounces in Weighing
Mode.
Note: After setting Weighing Resolution to high, the default display will show [ 0:00 0.00 ] with timer
in Dual Display Mode and Auto Start Modes.
Weighing Filter Setting [ FiLtEr ]
1. The Weighing Filter Setting determines the speed at which the load receptor responds to weight
and determines the weighing value. The larger the number, the more stable but slower the
weighing result will be. The number shown on the LED display indicates the current filter setting.
2. Press the Tare button to change the parameter.
Zero Tracking Setting [ trAcE ]
1. Zero Tracking is a function for automatically maintaining the zero indication within certain limits.
2. Off: It is not recommended to turn off Zero Tracking because the zero indication can drift easily as
the room temperature changes.
3. 0.5 d~3 d: For example, for standard resolution each division is 0.1 g, 3 d = 0.3 g. When Zero
Tracking is set to be 3 d, any initial weight between ± 0.3 g on the weighing pan will be zeroed out
gradually.
4. 2 d is recommended in general for the Acaia Lunar.
Zero Range Setting [ 0.rAnGE ]
1. The Zero Range Setting determines the range for which the Tare button executes zero operation
instead of tare operation.
2. When Zero Range is set to 2, the range for zero-setting will be 2% of the capacity, i.e., ± 40 g for
Acaia Lunar. By pressing the Tare button, any weight within ± 40 g is zeroed out by zero operation
while any weight that lies outside the range is tared out by tare operation.
3. If Zero Range is set to 100, the range for zero-setting will be 100% of the capacity, i.e., ± 2 kg for
Acaia Lunar. Therefore, instead of tare operation, zero operation would be executed in this setting
whenever the Tare button is pressed.
Notice: The difference between zero operation and tare operation is that zero operation would simply
ignore the weight and display as 0 while tare operation would deduct the weight from the weighing
result. However, zero operation does not increase the scale capacity.
Bluetooth Setup Setting [ bt_SEt ]
1. Off: Bluetooth disabled. The scale does not allow any Bluetooth connection.
2. On: Bluetooth enabled. The scale allows Bluetooth connection. The user may connect the scale
with Acaia apps.
Reset to Default Setting [ rESEt.d ]
Select [ YES ] to reset all settings to default value.