Mode 4 - Auto-Tare Timer Starts With Flow Mode - acaia AL010 User Manual

Table of Contents

Advertisement

Mode 4 - Auto-Tare Timer Starts with Flow Mode

Droplet and Square
Display
• In grams, the LED display shows [ 0:00 0.0 ].
• In ounces, the LED display shows [ 0:00 0.000 ].
• The timer displays from [ 0:00 ] to [ 9:59 ] and then stops.
Mode Description
• The auto-tare function operates when a stable weight is placed on the scale.
• The timer will start automatically when the flow of espresso is detected.
1
The droplet and square icon
indicate that you are in Auto-Tare
Timer Starts with Flow Mode.
3
The timer starts when the flow of
espresso is detected.
Action
Start Timer
Tare Weight
Stop Timer
Reset Mode
Switch Mode
This mode is designed for baristas who would like to
measure the time of the shot starting from the first few
drops of espresso. When the weight reading is stable,
the scale will perform the auto-tare operation. After
the scale detects the espresso flow, the timer starts
automatically. The timer will stop automatically when
the espresso flow stops.
2
4
Operation
The timer will start when the flow is detected
Tare function starts when a stable weight is placed on the scale
The timer will stop when flow is no longer detected
Double tap Tare button
Press and hold Power button
Place a cup on the scale, and it will
perform auto-tare.
The timer will stop automatically
when the espresso flow stops or the
cup is removed.
-
11