Electrical system
Side stand sensor: up/down
indication on the diagnostics instrument always down: check the connector: if not OK, re-
store; if it is OK, disconnect the two terminals from the sensor and check continuity to ground
of PIN 1: if there is no continuity, restore the cable harness; if there is, replace the sensor
indication on the diagnostics instrument always up: disconnect the terminals from the sensor
and check if there is continuity between the two PINS, with stand down: if there is continuity,
replace the sensor; if the circuit is open, it means that the brown/green cable from sensor
PIN 2 to VEHICLE connector PIN 70 is short circuit to ground: restore the cable harness
Bank angle sensor
(if applicable)
Function
It tells the vehicle position to the control unit
Operation / Operating principle
When the sensor is inverted, the circuit is closed
to ground: When the Marelli control unit detects
this ground connection, it does not enable start-up
or shuts off the engine.
Level in electrical circuit diagram:
Start-up enabling switches
Location:
on the vehicle: sensor placed in the
frame front niche.
connector: next to the sensor (2-ways
grey connector).
Electrical specifications:
Sensor in vertical position: open circuit
(resistance: 62 kOhm)
Sensor inverted: closed circuit (con-
tinuity)
Pin out:
1. Ground connection
2. Voltage 5V