Download Print this page

APRILIA RSV4 ABS 2009 Manual page 163

Advertisement

RSV4 ABS
out" (the latter status entails Urgent service being displayed on the instrument panel). If Throttle Self-
learning shows "Not carried out", go to stage 1. If it shows "Carried out", go to stage 2. Phase 1: current
errors have probably been detected by the control unit: solve these malfunctions and check the two
statuses. Throttle Self-learning can also be checked from the Parameter adjustment (screwdriver and
hammer) screen page. Stage 2: Carry out the Handle Self-learning from the Parameter adjustment
(screwdriver and hammer) screen page and check that Handle Self-learning status is Carried out. If not
OK the voltage detected on the throttle is out of scale (check with diagnosis instrument) or current errors
have been probably detected by the control unit: solve these malfunctions and repeat the procedure
Battery
Function
Electrically supply the vehicle: battery YTZ 10 S
MF is already activated, loaded and sealed; or, al-
ternatively, battery YT 12A - BS, which must be
activated and loaded.
Level in electrical circuit diagram:
Battery recharge
Location:
on the vehicle: under the saddle
connector: on the battery
Electrical specifications:8.6 Ah
Pin out:
1. Positive pole (red): approx. 12.6 V
2. negative pole (black): ground connection
DIAGNOSTICS INSTRUMENT: PARAMETERS
Battery voltage
Example value with key ON: 12.0 V
Example value with engine on: 14.2 V
In case of recovery, this value is set by the control
unit
Battery voltage pre Recovery
Example value with key ON: 12.0 V
Example value with engine on: 14.2 V
Value drawn from the signal read without taking
into account any recovery
CAUTION
Electrical system
ELE SYS - 163

Advertisement

loading

This manual is also suitable for:

Rsv4 abs 2010Rsv4 abs 2011