1. Apply 6V between TP5(+) and TP6(-) with current limit of PSU to 200mA.
-
2. Confirm that the charge current is ON/OFF.
3. SW to decrease current limit of PSU to 100mA.
4. Confirm that the charge current is stable.
1. Stop supplying 6V to TP5(+) and TP6(-).
-
2. Execute the command "charge".
3. Confirm that the returned value is 0x00 (hex).
1. Apply 2.3V ± 0.005V between TP3(+) and TP4(-).
-
2. Execute the command "readbatt".
3. Confirm:
98 < returned value < A8 (Hex)
4. Execute the command "WRTBAT2 XX".
XX: (returned value) - 06 (Hex)
1. Apply 2.40V between TP3(+) and TP4(-).
-
2. Confirm that there is no Speaker sound (Battery low alarm).
3. Apply 2.20V between TP3(+) and TP4(-).
4. Confirm that there is Speaker sound (Battery low alarm).
1. Execute the command "conttx".
TP19
2. Adjust the frequency of TP19 executing thecommand "setfreq 00 xx (where xx is the
value)" so that the reading of the frequency counter is 10.368000MHz ± 3Hz.
Procedure*
46
Check
IC1,D4,L4,
L5,Q2,Q3,
R6,D2,R22
C26,F1,R21
IC1,D4,L4,
L5,Q2,Q3,
R6,D2,R22
C26,F1,R21
IC1,D4,L4,
L5,Q2,Q3,
R6,D2,R22
C26,F1,R21
IC1,F1,R21
R4,C33,C12
C31,R17,R2
C10,C11,D6
IC1,L3,C57
IC3,X1,C16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-a141exs

Table of Contents