2003 Panasonic Communications Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law. 1. ABOUT LEAD FREE SOLDER (PbF: Pb free) Note: In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead.
temperature control and adjust it to 700°F ± 20°F (370°C ± 10°C). In case of using high temperature soldering iron, please be careful not to heat too long. - PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100°F (600°C).
1.2.1. Base Unit PCB (Component View) (Flow Solder Side View) Note: The locations of the “PbF“ mark is subject to change without notice. 1.2.2. Handset PCB (Component View) (Flow Solder Side View) Note: The locations of the “PbF“ mark is subject to change without notice. 1.2.3.
Close the cover as indicated by the arrow. - When you replace the batteries, part should be removed first. 4.2. Battery Charge At the time of shipment, the batteries are not charged. To charge, place the handset on the base unit.
- Battery life is dependent on use and conditions but in general when using fully charged Ni-MH batteries (700 mAh): Talk time: 10hrs approx. Standby time: 120hrs approx. - When using Ni-Cd batteries (250 mAh): Talk time: 4hrs approx. Standby time: 40hrs approx. (Times indicated are for peak performance) - The batteries reach peak performance after several full charge/ discharge cycles.
- Do not use non-rechargeable batteries. If non-rechargeable batteries are fitted and start charging, it may cause the leakage of the battery electrolyte. Please use only Panasonic P03P(Ni-MH) or P03H(Ni-Cd) batteries. 5. LOCATION OF CONTROLS 5.1. Base Unit 5.2. Handset...
Page 8
6. SETTINGS 6.1. Connection 6.1.1. Base Unit Plug in the AC adaptor and the telephone line cord in order 1, 2, 3, 4.
Page 9
- The telephone will not work during a power failure. We therefore recommend you use a standard telephone and T Adaptor to connect this Digital Cordless Phone to the line. Your Panasonic Sales Shop can offer you more information about connection possibilities.
Page 10
6.3. PIN Code 6.3.1. Base Unit - To exit the operation, press any time. For Service Hint: * : If the current 4-digit PIN is forgotten, press you will be able to enter new PIN. 6.3.2. Handset...
Page 11
- To exit the operation, press any time. For Service Hint: * : If the current 4-digit PIN is forgotten, press you will be able to enter new PIN. 6.3.3. Reset Base Unit PIN to Default (0000) -When There is NO Handset Registered- 6.3.3.1.
Page 12
2. Next, execute <initbspin.bat> by typing "initbspin". The PC display will be shown as below. 3. After that, turn off DC power supply (9V) to the jig, unplug AC adaptor, and remove pins on PCB. Then close the cabinet. The base pin returns to the default (0000) and you can register a handset to the base using the base PIN (0000).
Page 13
You can reset all of the handset settings to their initial settings. - To exit the operation, press any time. - *1: The factory preset is 0000. Handset Initial Settings Function Initial Setting Remarks (selectable options) Time Alarm Mode OFF/ON Alarm Time Clear OFF/Once/Daily...
6.5. Key Lock You can lock the handset dialling buttons. Only incoming calls are accepted while the key lock is on. The key lock is cancelled if the handset is turned off. When the key lock is on, emergency calls cannot be made until key lock is cancelled. is displayed (Refer to Handset Display ()) and all dialling buttons...
is displayed (Refer to Handset Display ()) on the LCD. 6.8. Call Restriction You can restrict selected handset(s) from dialling selected phone numbers. You can assign up to 10 call restriction numbers (up to 8 digits). If you dial a restricted number, the call does not connect and restricted number flashes.
- To exit the operation, press any time. - *1: The factory preset is 0000. - *2: The selected handset(s) will stop flashing. 6.10. Call BAR On/Off (Call Prohibition On/Off) You cannot make any dialling if call BAR is on. - To exit the operation, press any time.
Page 17
- To exit the operation, press any time. - *1 You can select one of 10 languages. If you set a language you cannot read, reset the handset to its initial settings. Press MENU DOWN RIGHT RIGHT 4-digit Handset PIN All handset setting will be reset to their initial settings, however, the Phonebook data will be saved.
Page 18
For Service Hint: icon will be displayed if the unit took a signal from Telephone Company as a Voice Message signal. In that case, press the left button of the Navigator Key for a while. 7.2. Before Requesting Help (Troubleshooting) If you experience any problems with the normal use of your apparatus, you should unplug it from the telephone outlet and connect a known working telephone in its place.
*1 When button is released, the display changes to the standby mode. *2 The display goes blank. 8.2. Making a Call *1 If you need correction, press CLEAR. Digit is cleared to the left, then enter numbers. 8.3. Answering a Call - Each ringer will start ringing with lower volume then gradually increase the volume when receiving a call.
Page 21
- To exit the operation, press any time. *1 For example, to set 7:15, enter 0715. *2 For example, to set the 16th of February, 2003, enter 160203. 8.5. Phonebook You can store up to 20 caller information in the phonebook. If you received a call from the same phone number you stored with a name in the phonebook, the display will show the caller’s name.
Page 23
*1 If there is no item stored in the phonebook, the display shows *2 Digits are cleared to the left of the flashing digit. *3 Digits are added to the left of the flashing digit. If you need to clear or add more than one digit, repeat the steps from 5.
Page 24
*2 If you need correction, press RIGHT or LEFT to move cursor then clear a character by pressing CLEAR, and/or enter digits. Digits are cleared or added to the left of the flashing digit. 8.5.4. Hot Key (: Speed Dial) You can assign the dialling buttons 1 through 9 as hot keys.
Shown in Fig.- To Remove Remove Lower Cabinet Screws (2.6 × 14)..(E) × 2 Main P.C. Board Main P.C. Board 10. ASSEMBLY INSTRUCTIONS 10.1. Warning When Constructing the Base Unit 11. TROUBLESHOOTING GUIDE Flow Chart...
Cross Reference: Check Power Bell Reception Check Battery Charge Check Link Check Handset Transmission Check Handset Reception SIGNAL ROUTE 11.1. Check Power 11.1.1. Base Unit Is the AC Adaptor inserted into AC outlet? (Check AC Adaptor’s specification.) Cross Reference...
Cross Reference: HOW TO CHECK THE HANDSET SPEAKER SIGNAL ROUTE 11.6. Check Caller ID Cross Reference: SIGNAL ROUTE 11.7. Bell Reception 11.7.1. Base Unit Note: BBIC is IC2. 11.7.2. Handset Cross Reference: Telephone Line Interface Check Link Note: BBIC is IC1. 12.
Page 32
12.1.1. Equipment Required - DECT tester: Rohde & Schwarz, CMD 60 is recommended. - Frequency counter: it must be precise to be able to measure 1Hz (precision; ±4ppm). Hewlett Packard, 53131A is recommended. - DC power: it must be able to output at least 1A current under 9V. - Digital multi-meter (DMM): it must be able to measure voltage and current.
Command name Function Example rdeeprom Read the data of EEPROM Type “rdeeprom 00 00 FF”, and the data from address “00 00” to “FF” is read out. readid Read ID (RFPI) Type “readid”, and the registered ID is read out. writeid Write ID (RFPI) Type “writeid 00 18 E0 0E 98”, and the ID...
Page 34
13.2.1. Connections 13.2.2. PC Setting 1. Open a window of MS-DOS mode from the start-up menu. 2. Change a directory to the one with “RTX_COM” contained. 3. Type “SET_COM 1” from the keyboard (when COM port 1 is used for the connection). 4.
Page 35
Symptom Remedy The base unit does not respond to a call from handset. Make adjustments in item ( )~(M) The base unit does not transmit or the transmit frequency is off. Make adjustments in item ( (H)~(J), (L) The transmit frequency is off. Make confirmation in item (H)~(J), (L) The transmit power output is low, and the operating distance between...
Page 36
Items Procedure* Check Adjustment Point 1. Confirm that the voltage between TP91 and GND is 4.0V ± 0.2V. 4.0V Supply D4,C40,Q9 Confirmation R41,R42,C4 D5,C75,C78 C69,C66,C6 1. Confirm that the voltage between J102 and GND is 0V ± 0.4V. VBACK Status IC2,Q8,C23 Confirmation C24,C25,C2...
Page 37
Items Procedure* Check Adjustment Point 1. Connect J1 (Telephone Socket) to DTMF tester. DTMF Generator IC2,R32,C2 2. Execute the command "hookoff" and "dtmf_up". Confirmation 3. Confirm that the high frequency (1477.06Hz) group is -8dBm ± 2dBm. 4. Execute the command "dtmf_lo". R23,C80,C1 5.
Page 38
Items Procedure* Check Adjustment Point (I) Modulatoin Check Follow steps 1 to 3 of (H) above. IC2,IC3,L1, and Adjustment C43,C78,C7 4. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/ div using data type Fig31. C69,C48,C7 5. Adjust the B-Field Modulation if required. (Execute the command "readmod"...
Page 39
Items Procedure* Check Adjustment Point Sensitivity Follow steps 1 to 3 of (H) above. IC2,IC3,L1, Receiver C43,C78,C7 4. Set DECT tester power to -88dBm. Confirmation 5. Confirm that the BER is < 1000ppm. C69,C48,C7 C66,C67,C7 C57,C73,L3 DA1,R66,R6 C55,C56,R7 R79,C54,C5 Timing Follow steps 1 to 3 of (H) above.
Page 40
Items Procedure* Check Adjustment Point RSSI Level Follow steps 1 to 3 of (H) above. IC2,IC3,L1, Confirmation C43,C78,C7 4. Set DECT tester power to -88dBm. 5. Execute the command "readrssi". C69,C48,C7 6. Confirm: 29 < returned value < 3E (hex) C66,C67,C7 C57,C73,L3 DA1,R66,R6...
Page 41
Items Procedure* Check Adjustment Point 1. Configure the DECT tester (CMD60) as follows; Receive Audio IC2,C21,R3 <Setting> Check and Adjustment -Test mode: FP C20,C11,R1 -Mode: Normal -PMID: 0000 2. Execute the command "testmode". R16,D3,R12 3. Initiate connection from DECT tester. 4.
Page 42
Items Procedure* Check Adjustment Point 1. Configure the DECT tester (CMD60) as follows; Transmit Audio IC2,R32,C2 <Setting> Check and Adjustment -Test mode: FP R23,C80,C1 -Mode: Normal -PMID: 0000 2. Execute the command "testmode". C13,R22,R2 3. Initiate connection from DECT tester. 4.
14.2. Adjustment Standard (Base Unit) When connecting the Simulator Equipments for checking, please refer to below. 14.2.1. Component View Note: (H) - (O) is refered to ADJUSTMENTS (BASE UNIT AND CHARGER UNIT) 14.2.2. Flow Solder Side View Note: (A) - (P) is refered to ADJUSTMENTS (BASE UNIT AND CHARGER UNIT) 14.3.
Symptom Remedy The movement of Battery Low indicator is wrong. Make confirmation in item (F)~(G) The handset does not respond to a call from base unit. Make adjustments in item ( (H), (J)~(N) The handset does not transmit or the transmit frequency is off. Make adjustments in item ( (H)~(K), (M) The transmit frequency is off.
Page 45
Items Procedure* Check Adjustment Point 1. Confirm that the voltage between TP18 and GND is 0V ± 0.4V. VBACK Status IC1,F1,R21 Confirmation R4,C33,L2 D1,C15,C2 C14,Q1,R3 R2,D2,R22 C26,R16,X1 1. BBIC Confirmation (Execute the command "getchk"). BBIC IC1,X1,C16 2. Confirm the returned checksum value. Confirmation Connection of checksum value and program number is shown below.
Page 46
Items Procedure* Check Adjustment Point 1. Apply 2.40V between TP3(+) and TP4(-). Battery low IC1,F1,R21 2. Confirm that there is no Speaker sound (Battery low alarm). Confirmation 3. Apply 2.20V between TP3(+) and TP4(-). 4. Confirm that there is Speaker sound (Battery low alarm). R4,C33,C12 C31,R17,R2 C10,C11,D6...
Page 47
Items Procedure* Check Adjustment Point (K) Frequency Offset Follow steps 1 to 4 of (I) above. IC1,IC3,C54 Confirmation 5. Confirm that the frequency offset is -50kHz ~ +50kHz. C66,C60,L3 C57,C55,C5 C62,R23,R2 C63,C64,C6 Sensitivity Follow steps 1 to 4 of (I) above. IC1,IC3,C54 Receiver 5.
Page 48
Items Procedure* Check Adjustment Point RSSI Level Follow steps 1 to 4 of (I) above. IC1,IC3,C54 Confirmation 5. Set DECT tester power to -88dBm. C66,C60,L3 6. Execute the command "readrssi" 7. Confirm that the returned value is 0x34 ± A (hex). C57,C55,C5 C62,R23,R2 C63,C64,C6...
Note: After the measuring, sock up the solder of TP. PC Setting () is required beforehand. The connection of adjustment equipment are as shown in Adjustment Standard (Handset) 15.2. Adjustment Standard (Handset) When connecting the Simulator Equipments for checking, please refer to below. Note: (A) - (P) is refered to ADJUSTMENTS (HANDSET)
17. HOW TO CHECK THE HANDSET SPEAKER 1. Prepare the digital voltmeter, and set the selector knob to ohm meter. 2. Put the probes at the speaker terminals as shown below.
20.3. Telephone Line Interface <Function> - Bell signal detection - Clip signal detection - ON/OFF hook circuit - Audio circuits Bell & Clip (: Calling Line Identification Presentation: Caller ID) signal detection: In the standby mode, Q2 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the TP3 (A) and TP40 (B) leads (when the telephone rings), the signal is transferred as follows;...
Page 55
20.4. Transmitter/Receiver Base Unit and Handset mainly consist of RF Module and DECT BBIC. Base Unit and Handset transmit/receive voice signal and data signal through the antenna on carrier frequency. Signal Pass: *Refer to SIGNAL ROUTE 20.4.1. Transmitter Block The voice signal input from the TEL LINE interface goes to RF Module (IC3) through DECT BBIC (IC2) as shown in BLOCK DIAGRAM (BASE UNIT) The voice signal passes through the analog part of IC2 where it is amplified and converted to a...
Page 56
EEPROM, LCD) - RF Module: IC3 - PLL Oscillator - Detector - Compress/Expander - Amplifier for transmission and reception 22.2. Power Supply Circuit/Reset Circuit Circuit Operation: When power on the Handset, the voltage is as follows; BATTERY(2.2 V ~ 2.6V: TP3) TP14(4V) IC3(6, 27), D3 IC1(37)
Battery voltage: V(Batt) < 2.3V The BBIC detects this level and " " starts flashing and "battery alarm" starts ringing. - Power Down Battery voltage: V(Batt) < 2.2V The BBIC detects this level and power down. 23. CIRCUIT OPERATION (CHARGER UNIT) 23.1.
Page 59
Description Hi-z Remarks PA_Driver_Amp PA_ON PA_OFF TX/RX SW RX_Data Data Data PLL_Strobe Latch Normal PLL_Data Active Active PLL_Clk Active Active TX_Data Active Active (NO USE) RF_System_Clk Active Active RESETQ Normal Reset VDDPM VSSO LOAD XTAL 10.368 MHz VDDLR VDDA VSSA Audio_Out_N Audio_Out_P Bandgap_Ref...
Description Hi-z Remarks VBACK (NO USE) (I_PD) (NO USE) (Fixed) (NO USE) (Fixed) (NO USE) (Fixed) (NO USE) (Fixed) (NO USE) (Fixed) KEY_IN No Key (NO USE) D.I/O (I_PD) (NO USE) D.I/O (I_PD) (NO USE) D.I/O (I_PD) (NO USE) D.I/O (I_PD) (NO USE) D.I/O...
Page 61
Description Hi-z Remarks LCD_SEGMENT Active LCD_COMMON Active LCD_COMMON Active LCD_COMMON Active LCD_COMMON Active LCD_COMMON Active LCD_COMMON Active PA_SW PA ON T/R SW Transmit RX_DATA Active SYEN Active SYDA Active SYCL Active TX_DATA Active KEY_IN No Key KEY_IN No Key KEY_IN No Key KEY_IN No Key...
Page 62
Description Hi-z Remarks MICN Reference Voltage RSSI P0.4 AD4N AD4P (NO USE) KEY_STRB Active KEY_STRB Active KEY_STRB Active LCD_SEGMENT Active LCD_SEGMENT Active LCD_SEGMENT Active KEY_STRB Active KEY_STRB Active LCD_SEGMENT Active LCD_SEGMENT Active VDD for EEPROM I2DAT D.I/O Active I2CLK D.I/O Active MODE (NO USE)
LCD_SEGMENT Active Description Hi-z Remarks LCD_SEGMENT Active LCD_SEGMENT Active LCD_SEGMENT Active LCD_SEGMENT Active LCD_SEGMENT Active LCD_SEGMENT Active LCD_SEGMENT Active LCD_SEGMENT Active LCD_SEGMENT Active LCD_SEGMENT Active 27. EEPROM LAYOUT (BASE UNIT) 27.1. Scope The purpose of this section is to describe the layout of the EEPROM (IC1) for the KX-TCD410 Base Unit.
Page 64
27.3. EEPROM Layout 27.3.1. General Setup Address Default Name Type Description Country Setting 0000-01 00 E0 EepromOscillator Frequency adjustment 0002 ModulationDeviation Modulation adjustment 0020 RFPI (ID for Base Unit) RFPI 0025-0026 00 00 AC (Base PIN code) AC code 0028 TBR22Test TBR22 test 0030-0034...
Page 65
Address Default Name Type Description Country Setting 09F1 Handset registration info - registration HsRegInfo.RegFlags 1=reg, 0=no reg 09F2 Handset registration info - EMC flags HsRegInfo.EmcFlags 6..7: not used 0..5: handset 1..6 info, 1=known , 0 unknown 09F3 RingMode Ring mode. Modes used in KAMMA4 and 21h.
Page 66
Address Default Name Type Description Country Setting 0F1C Detect CLIP detect configuration 0-2: Mode: 0: Learn mode, 1: DTMF only, 2: FSK only, 3: Generic mode, Russian CLIP only 3: Unused4 4: Onhook: 1=enable 0=disable 5: Offhookk: 1=enable 0=disable 6: Msgwaiting: 1=enable 0=disable 7: Unused7 0F37..38 3D 01...
The handset uses a 32k bit serial EEPROM (IC2) for storing volatile parameters. All parameters are set up before the handset the factory. Some of these are vital for the operation of the hardware so a set of default parameters is programmed before the actual hardware fine-tuning can be initiated.
Page 69
Address Default Name Type Description Country Setting 0100-0104 RFPI_1 (Base 1) RFPI for registration 1 0105 SerClass_1 Service class for registration 1 0106 LAL_1 Location area level for registration 0107 IPUI_LEN_1 IPUI length for registration 1 0108-0114 IPUI_1 IPUI for registration 1 0115 ZAP_1 ZAP for registration 1...
Page 70
Address Default Name Type Description Country Setting 0462 Language 00 = English 01 = Spanish 02 = French 03 = Italian 04 = Dutch 05 = Turkish 06 = Hungarian 07 = Portuguese 08 = Polish 09 = Command 0A = German 0467 FactoryLanguageSetting x Factory setting for language:...
Address Default Name Type Description Country Setting 0F36 GR-offset for Bit7: AOG volumestep 1 Bit6: AOG2 Bit5, bit0: Gain-receive (values ranging from 0x00 to 0x30, each step representing 1 dB) 0F37 GR-offset for Bit7: AOG volumestep 2 Bit6: AOG2 Bit5, bit0: Gain-receive (values ranging from 0x00 to 0x30, each step representing 1 dB) 0F38...
Page 72
29.2. Procedure 1. Tack the flat pack IC to the PCB by temporarily soldering two diagonally opposite pins in the correct positions on the PCB. Be certain each pin is located over the correct pad on the PCB. 2. Apply flux to all of the pins on the IC. 3.
34.2. Handset 34.3. Charger Unit 35. REPLACEMENT PARTS LIST 1. RTL (Retention Time Limited) Note: The marking (RTL) indicates that the Retention Time is limited for this item. After the discontinuation of this assembly in production, the item will continue to be available for a specific period of time.
Page 80
components, only use specified manufacture’s parts. 3. The S mark means the part is one of some identical parts. For that reason, it may be different from the installed part. 4. ISO code (Example: ABS-94HB) of the remarks column shows quality of the material and a flame resisting grade about plastics.
Page 81
Ref. No. Part No. Part Name & Description Remarks PCB1 PQWP1D410NZH MAIN P.C.BOARD ASS'Y (RTL) (ICS) PQWI1D410NZH IC (*1) C2HBAK000004 PQVILM1117MP (TRANSISTORS) 2SA1625 TRANSISTOR(SI) PQVTBF822T7 TRANSISTOR(SI) 2SD1994A TRANSISTOR(SI) B1ADGE000004 TRANSISTOR(SI) PQVTDTC143K TRANSISTOR(SI) (DIODES) PQVDS1ZB60F1 DIODE(SI) MA1Z300 DIODE(SI) B0JAME000085 DIODE(SI) MA2Z74800L DIODE(SI) B0DDCM000001 DIODE(SI)
Page 84
(*2)When replacing IC2, data need to be written to it with PQZZTCD410NZ. Ref. No. Part No. Part Name & Description Remarks PCB100 PQWP1D410NZR MAIN P.C.BOARD ASS'Y (RTL) (for KX-TCD412NZM) PCB100 PQWP1D142NZR MAIN P.C.BOARD ASS'Y (RTL) (for KX-A142NZM) (ICs) C2HBAK000003 PQWI1D410NZR...
PQWPA142ESCH MAIN P.C.BOARD ASS'Y (RTL) B0JAME000085 DIODE(SI) (JACK) PQJJ1B4Y JACK (RESISTORS) ERJ1WYJ220 ERJ1WYJ270 35.4. Accessories and Packing Materials 35.4.1. KX-TCD412NZM Ref. No. Part No. Part Name & Description Remarks PQLV19ALZ AC ADAPTOR (for Base Unit) PQLV200ALZ AC ADAPTOR (for Charger Unit) PQJA87S...
Page 101
CHG terminal is properly fit in the cabinet. CHG terminal comes out of rib by pulling black lead wire when opening the cabinet and turning the PCB over. The terminal cannot have enough elastic force, cannot have good contact with handset, and it will result in charge problem.
Page 102
AF Volt Meter Tel Simulator DECT tester CMD60 (N) (O) (H) (I) (J) (K) (L) AF Generator JMP2 JMP6 JMP5 A201 JMP7 JMP8 RLY1 JMP4 JMP3 JMP1 A202 B C E LED1...
Page 103
Digital Volt Meter (D) (E) (F) (G) 12Ω/2W (H) (N) (O) Digital Digital To PC (JIG) Volt Meter Volt Meter J105 J101 TP84 TP82 TP187 CHARGE+ CHARGE TP97 TP50 TP45 TP188 TP91 Frequency Counter TP89 TP40 TP39 To DECT tester TP101 TP90 DTMF...
Page 105
(F) (G) 2.20V ~ 2.40V TP16 TP12 TP13 TP17 TP14 TP19 AF SG DECT TESTER CMD60 TP18 TP10 Digital DECT tester Volt Meter CMD60 AF Volt Meter Oscilloscope DECT TESTER CMD60 Digital (I) (J) (K) (L) (M) Volt Meter (N) (O) (P) Frequency (D) (E) Current...
Page 106
ADPCM RSSI Front End Codec Filter SYRI Interface SYEN HOOK RF Module DTXAF Bell/Caller ID DTXAF Interface Limit CHARGE XTAL Register CONTACT 10.368 BBIC VUNREG 4.0V to AC Adaptor Reg. EEPROM 4.0V 2.65V Reg. 2.65V KX-TCD412NZM BLOCK DIAGRAM (BASE UNIT)