Panasonic KX-TCD410SLS Service Manual page 42

Table of Contents

Advertisement

Items
(N)
Receive Audio
*
Check and
Adjustment
Adjustment
Point
1. Configure the DECT tester (CMD60) as follows;
ANT
<Setting>
J1
-Test mode: FP
-Mode: Normal
-PMID: 0000
2. Execute the command "testmode".
3. Initiate connection from DECT tester.
4. Execute the command "hookoff".
5. Execute the command "openau".
6. Connect J1 (Telephone Socket) to Tel-simulator which is connected with 600
7. Set line voltage to 48V and line current to 40mA.
8. Connect DECT tester to Tel-simulator.
9. Input audio signal (200mVrms/1kHz tone) to Tel-simulator.
<DECT tester setting>
-Scramble: On
-AF Gen to ADPCM: Off
-AF Meter Input: ADPCM
-AF Gen Frequency: 1000Hz
-AF Gen Level: 200mVrms
10. Confirm hearing tone: 360mVrms ± 60mVrms
11. Adjust audio level if required. (Make sure current value using "getmicgain". And then
execute the command "setmicgain xx", where xx is the value.)
12. Confirm that the B-field audio distortion with DECT tester is < 5 %.
Procedure*
42
Check
IC2,C21,R3
C20,C11,R1
R16,D3,R12
Q2,R7,R8,
.
Q3,R9,R10
D2,C1,C2,
R77,IC3,L1
C43,C78,C7
C69,C48,C7
C66,C67,C7
C57,C73,L3
DA1,R66,R6
C55,C56,R7
R79,C54,C5

Advertisement