7 Troubleshooting
PG encoder is disconnected or is
not wired properly, or the PG
option or PG encoder are
damaged.
Digital Operator Display
oFA00
Cause
Non-compatible option is
connected to drive port CN5-A.
Digital Operator Display
oFb00
Cause
Non-compatible option is
connected to drive port CN5-B.
Digital Operator Display
oFb01
Cause
Option at drive port CN5-B was
changed during run.
Digital Operator Display
oFC01
Cause
Option at drive port CN5-C was
changed during run.
Digital Operator Display
Cause
Overshoot is occurring.
Incorrect speed feedback scaling
when terminal RP is used as
speed feedback input in V/f
control.
Incorrect PG encoder pulse
number set.
Inappropriate parameter settings.
32
• Check PG encoder wiring and make sure all wiring including shielded wiring is
properly connected.
• If the problem continues after cycling power, replace the PG option or the PG
encoder.
Non-compatible option is connected to drive port CN5-A.
Use only compatible options. Connect PG-X3 to CN5-B or CN5-C. For other
options, refer to the Installation Manual for that option.
Non-compatible option is connected to drive port CN5-B.
Use only compatible options. For other options, refer to the Installation Manual
for that option.
Option Connection Error at drive port CN5-B
Switch the power off and reconnect the option.
Option Connection Error at drive port CN5-C
Switch the power off and reconnect the option.
Overspeed
oS
The motor speed feedback exceeded the F1-08 setting.
• Increase the settings for C5-01 (Speed Control Proportional Gain 1) and reduce
C5-02 (Speed Control Integral Time 1).
• Enable Feed Forward Control and perform Inertia Auto-Tuning in CLV.
• Set H6-02 to the value of the speed feedback signal frequency when the motor
runs at the maximum speed.
• Adjust the input signal using parameters H6-03 through H6-05.
Check and correct parameter F1-01.
Check the setting for the overspeed detection level and the overspeed detection
time (F1-08 and F1-09).
YASKAWA ELECTRIC TOBP C730600 37C 1000-Series Option PG-X3 Installation Manual
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pg-x3

Table of Contents