tep 5:
Flame Monitoring
Control ystem
16
lame Rod
U.V. Scanner
The flame monitoring control system consists of two main
components:
Flame Sensor
Flame Monitoring Control
lame Sensor
Two types can be used on a Ratio ir Burner:
flame rod
U.V. scanner
Flame rods are available only for the R 0100 Burner model
with alloy or SiC tube. Further information can be found in:
 Info Guide 832
U.V. scanner can be used on all Ratio ir Burner sizes.
Further information can be found in:
 Info Guide 852; 90º U.V. scanner
 Info Guide 854; straight U.V. scanner
 Instruction Manual 855; Solid State UV/IR scanner
 Info Guide 856; self-check U.V. scanner.
lame Monitoring Control
The flame monitoring control is the equipment that processes
the signal from the flame rod or the U.V. scanner.
For flame monitoring control you may select several options:
 flame monitoring control for each burner: if one burner
goes down, only that burner will be shut off
 multiple burner flame monitoring control: if one burner goes
down, all burners will be shut off
There are three recommended flame monitoring controls:
 Bi-flame series; see Instruction Manual 826
 Multi-flame series 6000; see Instruction Manual 820
 Veri-flame; see Instruction Manual 818
Other manufacturer’s flame monitoring systems can be used
with the burner if spark is maintained for a fixed time interval
and is not interrupted when a flame signal is detected during
trial for ignition.