Functions in relation to the Steinel Connect app:
– Display of current network configuration.
– Display of current sensor values.
– Setting the TruePresence parameters.
LED function
Starting up: LED flashes blue rapidly for 30 seconds.
Initialisation: LED permanently lights up blue.
Normal mode: LED OFF.
Identification: LED slowly flashes blue.
Firmware update: LED rapidly flashes cyan.
Error: LED rapidly flashes red.
Factory settings for configuring network:
DHCP is factory-activated.
If no DHCP server is available, the sensor is configured
as followed:
IP address: 192.168.1.200
Subnet mask: 192.168.1.0/24
User password: updwd 123
Administrator code: adm123
Make LAN connection with the sensor
• Start web browser.
DHCP is factory-activated.
• Check which IP address the sensor has been given.
Use the IP address to open the web interface. If no
DHCP server is available, the sensor is configured as
followed:
– IP address: 192.168.1.200
– Sub-network mask: 192.168.1.0/24
In this case, the computer must be set to the same subnet
(192.168.1.0/24).
A customised network configuration can be set up via the
web interface.
User password: updwd123
Administrator code: adm123