Fujitsu AUYG18LVLB Design & Technical Manual page 304

Simultaneous multi
Hide thumbs Also See for AUYG18LVLB:
Table of Contents

Advertisement

9-2. Error code
If an error occurs, the LED will light up to display the error location and the error code.
¢ Error display mode
Display when an error occurs.
NOTE: Check that the "ERROR" LED blinks, then press the [ENTER] button once.
¢ Error code check table
PUMP DOWN
POWER/
ERROR
MODE
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
Display mode
: Lights on
: Lights off
: Blink (0.5s Lights on / 0.5s Lights off)
( ) : Number of ashing
9-2. Error code
PUMP
POWER
ERROR
DOWN
MODE
(L1)
Blink
(Hi speed)
Sign "
": Lights off, "
": Lights on
LED display
LOW NOISE
PEAK CUT
(L1)
(L2)
(L3)
(L4)
(1)
(1)
(1)
(1)
(2)
(2)
(5)
(15)
(6)
(2)
(6)
(3)
(6)
(5)
(7)
(1)
(7)
(2)
(7)
(3)
(7)
(3)
(7)
(4)
(7)
(7)
(8)
(4)
(8)
(6)
(8)
(6)
(8)
(6)
(9)
(4)
(9)
(5)
(9)
(7)
(9)
(8)
(9)
(9)
(10)
(1)
(10)
(3)
(10)
(5)
LOW
NOISE
(L2)
(L3)
(L4)
Description
(L5)
(L6)
Serial communication error
Indoor unit capacity error
Indoor unit error
Outdoor unit main PCB error
Inverter PCB error
P I
M
e
r r
r o
Discharge temp. sensor error
Compressor temp. sensor error
Outdoor unit Heat Ex. sensor error
Outdoor temp. sensor error
Heat sink temp. sensor error
Current sensor error
Pressure sensor error
r T
p i
d
e
e t
t c
o i
n
Compressor motor control error
Outdoor unit fan motor 1 error
Outdoor unit fan motor 2 error
4-way valve error
Discharge temp. 1 error
Compressor temp. error
Pressure error 2
- 296 -
PEAK
CUT
(L5)
(L6)
Remark
Serial forward transmission error immediately after
operation
Serial forward transmission error during operation
Indoor unit capacity error
Indoor unit error
Outdoor unit PCB model information error
Inverter error
r T
p i
t
r e
m
n i
l a
L
e
r r
r o
Discharge temp. sensor 1 error
Compressor temp. sensor 1 error
Heat Ex. middle temp. sensor error
Outdoor unit Heat Ex. liquid temp. sensor error
Outdoor temp. sensor error
Heat sink temp. sensor error
Current sensor 1 error (stoppage permanently)
High pressure switch 1 error
Outdoor unit discharge pressure sensor error
Outdoor unit suction pressure sensor error
r T
p i
d
e
e t
t c
o i
n
Rotor position detection error (stoppage permanently)
Duty error
Duty error
4-way valve error
Discharge temp. 1 error
Compressor 1 temp. error
Low pressure error
9. Check and test

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents