4. Connect the cable to the terminals on the front case.
Fix the cable together with the sheath with the cable tie. Cut off the excess cable tie.
CAUTION
• Be careful to avoid breaking the cable by over-tightening the cable tie.
• When connecting the remote controller cables, do not over-tighten the screws.
7-5. Wired remote controller (UTY-RVNYM: Optional part)
Tightening torque
Terminal screw
1. 12V (Red)
2. Signal (White)
3. COM (Black)
To avoid an excessive tension or pressure to the terminal block,
fix the remote controller cable with the cable tie properly.
Cable tie
Remote controller
cable (sheath)
2 mm
Good
Hole for cable tie
Prohibited
- 254 -
0.8 to 1.2 N•m
7. Remote controller