¢ External input
With using external input function, on/off status of "Low noise mode" and "Peak cut mode" can be
specified by the external signal.
Low noise mode
In following condition, the operating noise of the outdoor unit reduces comparing from the one in nor-
mal operating condition:
The air conditioner is set to the "Low noise mode" when closing the contact input of a commercial
timer or on/off switch to a connector on the control PCB of the outdoor unit.
NOTE: Product performance may drop depending on some conditions such as the outdoor temper-
ature.
• Circuit diagram example (CN131)
Outdoor unit
control PCB
Connector
CN131
Input signal
Low noise mode
• Optional part
Part name
External connect kit
6-2. Outdoor unit
Input
Low noise mode
Peak cut mode
—
—
Compressor status
• Contact capacity: DC 24 V or more, 10 mA or more.
Connected unit
• *: Make the distance from the PCB to the connected
Example: Switch
• Construct a circuit as shown in this figure with using op-
• Input signal: On in "Low noise mode"
*10 m
• Input signal: Off in normal operation
• To set the level of "Low noise mode", refer to
Signal
Locally purchased
On
Off
On
Off
Model name
UTY-XWZXZ3
Output
—
—
For details, refer to external input and
Error status
unit within 10 m.
tional parts mentioned below.
noise mode"
on page 282.