Endress+Hauser Ceraphant T PTC31 Operating Instructions Manual

Endress+Hauser Ceraphant T PTC31 Operating Instructions Manual

Process pressure measurement
Hide thumbs Also See for Ceraphant T PTC31:

Advertisement

Operating Instructions
Ceraphant T PTC31, PTP31, PTP35
Process pressure measurement
AUTHORIZED DISTRIBUTOR:
InstrumentsAndControl.com
Houston, Texas USA
sales@InstrumentsAndControl.com
832-615-3588

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Ceraphant T PTC31

  • Page 1 Operating Instructions Ceraphant T PTC31, PTP31, PTP35 Process pressure measurement AUTHORIZED DISTRIBUTOR: InstrumentsAndControl.com Houston, Texas USA sales@InstrumentsAndControl.com 832-615-3588...
  • Page 2: Serial Number

    Ceraphant T PTC31, PTP31, PTP35 Order code 00X00-XXXX0XX0XXX Ser. No.: X000X000000 TAG No.: XXX000 Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
  • Page 3: Table Of Contents

    Ceraphant T PTC31, PTP31, PTP35 Table of contents Table of contents 1 Safety instructions ..........4 1.1 Designated use .
  • Page 4: Safety Instructions

    Safety instructions Ceraphant T PTC31, PTP31, PTP35 Safety instructions Designated use The Ceraphant T is a pressure switch for measuring and monitoring absolute and gauge pressures. The device has been safely built with state-of-the-art technology and meets the applicable requirements and EC Directives. It can, however, be a source of danger if used incorrectly or for anything other than the designated use.
  • Page 5: Identification

    Ceraphant T PTC31, PTP31, PTP35 Identification Identification The following options are available for identification of the measuring device: • Nameplate specifications • Order code with breakdown of the device features on the delivery note • Enter serial numbers from nameplates in W@M Device Viewer (www.endress.com/deviceviewer): All information about the measuring device is displayed.
  • Page 6: Ce Mark, Declaration Of Conformity

    The device complies with the applicable standards and regulations as listed in the EC declaration of conformity and thus complies with the statutory requirements of the EC Directives. Endress+Hauser confirms the successful testing of the device by affixing to it the CE mark.
  • Page 7: Installation

    Ceraphant T PTC31, PTP31, PTP35 Installation Installation Incoming acceptance, storage • Incoming acceptance: Check the packaging and the device for damage. Check that the goods delivered are complete and nothing is missing. • Storage: Storage temperature -40...+85 °C (-40 to +185 °F)
  • Page 8: Post-Installation Check

    Installation Ceraphant T PTC31, PTP31, PTP35 3.2.1 Mounting instructions • Do not mount the device in the product flow or at a point where it could be affected by pressure pulses • Calibration and functional testing are easier if the device is mounted downstream of a shut-off assembly •...
  • Page 9: Wiring

    Ceraphant T PTC31, PTP31, PTP35 Wiring Wiring DC voltage version with M12 connector A2’ ➀ L– L– A3’ Diag. 4...20mA 4...20mA L– L– P01-PTx3xxxx-04-xx-xx-xx-002 Fig. 3: Ceraphant T with M12x1 connector A1: 1x PNP switch output A2: 2x PNP switch outputs R1 and m (R2) A2’: 2x PNP switch outputs R1 and m (diagnosis/break contact with adjustment "DESINA")
  • Page 10: Dc Voltage Version With Cable

    Wiring Ceraphant T PTC31, PTP31, PTP35 DC voltage version with cable C2’ ➀ L– L– GNYE GNYE C3’ 4...20mA 4...20mA Diag. L– L– GNYE GNYE P01-PTx3xxxx-04-xx-xx-xx-004 Fig. 5: Ceraphant T with cable connection C1: 1x PNP switch output C2: PNP switch outputs R1 and m(R2) C2’: PNP switch outputs R1 and m (diagnosis/break contact with adjustment "DESINA")
  • Page 11: Operation

    Ceraphant T PTC31, PTP31, PTP35 Operation Operation On-site operation The Ceraphant T is operated by means of three keys. Note! Only use instruments with a blunt tip for operation (e.g. ballpoint pen). Sharp instruments (e.g. needles, tweezers, pins) can destroy the operating unit.
  • Page 12 Operation Ceraphant T PTC31, PTP31, PTP35 5.1.1 Navigating in the operating menu b a r > 3 s SAVE > 3 s P01-PTx3xxxx-19-xx-xx-xx-005 Fig. 7: Navigating in the operating menu A Function group selection B Function selection ➀ Enter the operating menu –...
  • Page 13 Ceraphant T PTC31, PTP31, PTP35 Operation 5.1.2 Structure of the operating menu The structure below shows all the possible fields of the operating menu. P01-PTx3xxxx-19-xx-xx-xx-100 Fig. 8: Operating menu: A function groups, B functions, C settings Endress+Hauser...
  • Page 14: Operation With Personal Computer

    Operation Ceraphant T PTC31, PTP31, PTP35 Operation with personal computer The device can be configured with the configuration software ReadWin® 2000 or FieldCare. For the connection between the USB port of the computer and the device a configuration kit (e.g. TXU10 or FXA291)) is necessary.
  • Page 15 Ceraphant T PTC31, PTP31, PTP35 Operation 5.2.1 Additional operating options In addition to the operating options listed in the previous "On-site operation" section, the ReadWin 2000 or FieldCare configuration software provides further information on the Ceraphant T: Function group Description...
  • Page 16: Commissioning

    Commissioning Ceraphant T PTC31, PTP31, PTP35 Commissioning Function check Carry out a post-installation and a post-connection check as per the checklist before commissioning the device. • "Post-installation check" see  Chap. 3.3 checklist • "Post-connection check" see  Chap. 4.6 checklist...
  • Page 17: Output Setting

    Ceraphant T PTC31, PTP31, PTP35 Commissioning Base Basic settings Note! The procentage specification applies to the upper range limit. Factory setting Output setting • Hysteresis function: The hysteresis function enables two-point control via a hysteresis. Depending on the pressure p, the hysteresis can be set via the switch point SP and the switch-back point RSP.
  • Page 18 Commissioning Ceraphant T PTC31, PTP31, PTP35 OUT/OUT2 Output/output 2 Switching characteristic HYNO Hysteresis/NO contact HYNC: Hysteresis/NC contact WINO: Window/NO contact WINC: Window/NC contact 4...20 mA: Analog output (only if available) Switch point value Switch point 0.5...100 % in increments of 0.1 % of selected unit (min.
  • Page 19: Service Function Setting

    Ceraphant T PTC31, PTP31, PTP35 Commissioning 4 - 20 Analog output Value for 4 mA Enter lower range value in (LRV) increments of 0.1 % of selected unit Value for 20 mA Enter upper range value in (URV) increments of 0.1 % of...
  • Page 20: Maintenance

    Maintenance Ceraphant T PTC31, PTP31, PTP35 SERV Service functions Simulation OFF: No simulation output 1 or 2 OPEN: Switch output open CLOS: Switch output closed 3.5: Simulation values for analog output in mA (3.5/4.0/8.0/12.0/16.0/ 20.0/21.7) Max. indicator Display of max. measured process value Min.
  • Page 21: Accessories

    Ceraphant T PTC31, PTP31, PTP35 Accessories Accessories Process connection • Ceraphant T PTC31: The sensor module and the process connection are connected together and cannot be separated. • Ceraphant T PTP31, PTP35: The process connection is an adapter and the sensor module has an adapter thread. As a result, the process connection can easily be changed at a later stage.
  • Page 22 Accessories Ceraphant T PTC31, PTP31, PTP35 8.1.1 Adapter change The adapter can be changed on PTP31 and PTP35. PTP31 PTP35 P01-PTx3xxxx-17-xx-xx-xx-001 Fig. 13: Changing the adapter ➀ Sensor module with adapter thread ➁ Standard O-ring ➂ Adapter Please note the following when changing the adapter: •...
  • Page 23 Ceraphant T PTC31, PTP31, PTP35 Accessories 8.1.2 Adapter versions • PTP31: order numbers for thread adapter versions. Version AC: order no. 52023980 Version AD: order no. 52023981 Version AE: order no. 52023982 Version AF: order no. 52023983 Version BA: order no. 52023984 Version CA: order no.
  • Page 24 Accessories Ceraphant T PTC31, PTP31, PTP35 • PTP35: order numbers for Clamp adapter versions (EHEDG, 3A). SW28 AF28 Version DB: order no. 52023994 Version DL: order no. 52023995 Ø43.5 (1.7) Ø50.5 (2.0) Optional with inspection certificate 3.1: SW32 Version DB: order no. 52024001 AF32 Version DL: order no.
  • Page 25: Welding Bosses

    Ceraphant T PTC31, PTP31, PTP35 Accessories Welding bosses 8.2.1 Welding boss with sealing taper • Welding boss for flush mounting process connection G1A with metallic sealing taper (version BA for PTP35) Material: AISI 316L Order number: 52005087 • Optional with inspection certificate 3.1 ø50 (1,97)
  • Page 26: Electrical Connection

    Accessories Ceraphant T PTC31, PTP31, PTP35 Electrical connection 8.3.1 Plug-in jack, connecting cable • M12x1 plug-in jack. Connection to M12x1 housing connector Materials: Body PA, coupling nut Cu Zn, brass, nickeled. Protection: IP 67 (fully locked). P01-PMP13xxx-00-xx-00-xx-003 Order number: 52006263 •...
  • Page 27: Readwin

    Ceraphant T PTC31, PTP31, PTP35 Accessories ReadWin • Configuration kit for PC-programmable transmitters. Setup program and interface cable for PCs with USB port. Adapter for transmitters with 4-pin post connector. Order code: TXU10-AA ® • ReadWin 2000 is supplied with the...
  • Page 28: Trouble-Shooting

    Trouble-shooting Ceraphant T PTC31, PTP31, PTP35 Trouble-shooting Errors and warnings If an error in the device occurs, the colour of the status LED changes from green to red and the background illumination of the digital display changes from blue to red. The measured value and message are displayed alternately.
  • Page 29: Repair

    The measuring device must be returned if repairs or a factory calibration are required, or if the wrong measuring device has been ordered or delivered. According to legal regulations, Endress+Hauser, as an ISO-certified company, is required to follow certain procedures when handling returned products that are in contact with medium.
  • Page 30: Change Status - History

    Technical data Ceraphant T PTC31, PTP31, PTP35 Change status - history Release no. device Changes 1.00 1.01 New analog electronics 1.02 Modification sensor units 1.03 Internal device modification 1.04 Internal device modification 1.05 Internal device modification Technical data For technical data, please refer to the Technical Information Ceraphant T TI00384P.
  • Page 31: Index

    Ceraphant T PTC31, PTP31, PTP35 Index Index Adapter change ......22 Adapter versions ......23 Additional operating options .
  • Page 32 www.endress.com/worldwide KA00225P/00/EN/16.15 71302114 FM+SGML 9.0 71302114...

This manual is also suitable for:

Ceraphant t ptp31Ceraphant t ptp35

Table of Contents