30
www.electrolux.com
12.1 Building In
600
min. 560
590
12.2 Securing the appliance to
the cabinet
548
558
min. 550
20
16
573
5
3
548
min. 550
558
16
20
min. 560
573
5
3
A
12.3 Electrical installation
21
114
This appliance is supplied with a main
plug and a main cable.
589
594
12.4 Cable
Cable types applicable for installation or
595 +/-1
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05
VV-F, H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
21
Total power (W)
114
maximum 1380
589
594
maximum 2300
maximum 3680
595
+/-1
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
B
The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
Section of the ca‐
ble (mm²)
3 x 0.75
3 x 1
3 x 1.5