Working with alarms
4. Use the navigation pad to select Insulation alarm. This displays a dialog box.
5. Use the navigation pad to set the following parameters:
• Outdoor temperature: The current outdoor temperature.
• Indoor temperature: The current indoor temperature.
• Thermal index: The insulation level, an integer between 0 and 100.

16.3 Working with condensation alarms

16.3.1 General

The Condensation alarm can detect areas with potential moisture problems. You can set
the relative humidity above which the camera will colorize the image.

16.3.2 Procedure

Follow this procedure:
1. Push the navigation pad to display the menu system.
2. Use the navigation pad to go to Color.
3. Push the navigation pad.
4. Use the navigation pad to select Condensation alarm. This displays a dialog box.
5. Use the navigation pad to set the following parameters:
• Atmospheric temperature: The current atmospheric temperature.
• Relative humidity: The current relative humidity.
• Relative humidity limit: The relative humidity level at which you want the alarm to
be triggered—100% indicates that the water vapor condenses as liquid water (=
dewpoint).
#T559845; r. AA/ 8324/8526; en-US