4.6

Securing the burner to the boiler

Detach the combustion head from the burner (Fig. 11):
 disconnect the oil pipes by unscrewing the two connectors 6);
 loosen the 4 screws 3) and remove the cover 1);
 disengage the swivel coupling 14) from the graduated sector;
 remove the screws 2) from the slide bars 5);
 remove the 2 screws 4) and pull the burner back on slide bars
5) by about 4";
20097675
4.7

Electrode position

Make sure that the electrodes are positioned as
shown in Fig. 12.
WARNING
4.8

Ignition pilot adjustment

Place the pilot and electrode as shown in Fig. 13.
The pilot works correctly at pressures ranging from 3-4" WC.
Model
RLS 130/EV
20096088
Installation
1
2
3
A
15/ 64"
3
Tab. L
18
 install the extension bars 31)(Fig. 5, page 10) and re-screw
the screws 2) including the safety plate 15);
 disconnect the electrode wires and then pull the burner com-
pletely off the slide bars.
15
5
4
4 "
14
6
D10108