Download Print this page

Clenergy PV-ezRack PostMount 4-A Installation Manual

Hide thumbs Also See for PV-ezRack PostMount 4-A:

Advertisement

Quick Links

PV-ezRack PostMount 4-A
Content
...................................................................................................................12
Updated on 2017/11/30
with ECO Rail
Installation Guide V2.0
...............................................................................................................1
.........................................................................................2
....................................................................................................3
.........................................................................................7

Advertisement

loading
Need help?

Need help?

Do you have a question about the PV-ezRack PostMount 4-A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Clenergy PV-ezRack PostMount 4-A

  • Page 1: Table Of Contents

    PV-ezRack PostMount 4-A with ECO Rail Installation Guide V2.0 Content 1. Introduction .......................1 2. Tools and Components ..................2 3. System Overview ....................3 4. Installation Instructions ..................7 5. Warranty ........................12 Updated on 2017/11/30...
  • Page 2: Introduction

    (2)product installation specification; The PV-ezRack PostMount 4-A parts, when installed in accordance with this guide, will be structurally adequate and will meet the AS/NZS1170.2:2011 Amdt 3-2012 standard. During installation and especially when working on the ground please comply with the appropriate occupational health and safety regulations.
  • Page 3: Tools And Components

    Pipe Diameter Pipe Diameter Angle Bracket Adjustable Tube 2 / 12 No. 999-1009, Min’an Avenue, Xiang’an 01/10 Duerdin , Xiamen China 361006 Clayton VIC 3168 Tel: +86-592-5781288 Tel: +61-3-90176688 Fax: +86-592-5782298 Fax: +61-3-90176668 Email: sales@clenergy.com.cn Email: sales@clenergy.com.au Website: www.clenergy.com.cn Website: www.clenergy.com.au...
  • Page 4: System Overview

    3. System Overview 3.1 Overview of PV-ezRack PostMount 4-A 1. Universal Clamp 5. Rectangular Tube-Master 2. PM4-A Pole 6. Angle Bracket 3. Steel Cap Assembly 7. ECO Rail 4. Adjustable Tube 8. U bolt for Tube140 3 / 12 No. 999-1009, Min’an Avenue, Xiang’an...
  • Page 5 (5)Avoid working at high temperatures, 3.Safe Torques Please refer to safe torques defined in this guide. In case power tools are required, Clenergy recommends the use of low speed only. High speed and impact drivers increase the risk of bolt galling (deadlock) If deadlock occurs and you need to cut fasteners please make sure that there is no load on the fastener before you cut it.
  • Page 6 4. These steps should be applied for every stainless steel nut and bolt assembly. 5 / 12 No. 999-1009, Min’an Avenue, Xiang’an 01/10 Duerdin , Xiamen China 361006 Clayton VIC 3168 Tel: +86-592-5781288 Tel: +61-3-90176688 Fax: +86-592-5782298 Fax: +61-3-90176668 Email: sales@clenergy.com.cn Email: sales@clenergy.com.au Website: www.clenergy.com.cn Website: www.clenergy.com.au...
  • Page 7 All drawings and dimensions in this installation guide are for a generic reference. The Clenergy PostMount 4-A is to be optimized to site specific conditions for each project and documented in a construction drawing. As a result, major components of the Clenergy PostMount 4-A may be provided in section sizes and lengths that vary from those shown in this guide.
  • Page 8: Installation Instructions

    Recommended Torque: M20: 215~220Nm 7 / 12 No. 999-1009, Min’an Avenue, Xiang’an 01/10 Duerdin , Xiamen China 361006 Clayton VIC 3168 Tel: +86-592-5781288 Tel: +61-3-90176688 Fax: +86-592-5782298 Fax: +61-3-90176668 Email: sales@clenergy.com.cn Email: sales@clenergy.com.au Website: www.clenergy.com.cn Website: www.clenergy.com.au...
  • Page 9 All the head of bolts should be at the same side. 8 / 12 No. 999-1009, Min’an Avenue, Xiang’an 01/10 Duerdin , Xiamen China 361006 Clayton VIC 3168 Tel: +86-592-5781288 Tel: +61-3-90176688 Fax: +86-592-5782298 Fax: +61-3-90176668 Email: sales@clenergy.com.cn Email: sales@clenergy.com.au Website: www.clenergy.com.cn Website: www.clenergy.com.au...
  • Page 10 At the place refer to②,if there exist  any clearance between the 9 / 12 No. 999-1009, Min’an Avenue, Xiang’an 01/10 Duerdin , Xiamen China 361006 Clayton VIC 3168 Tel: +86-592-5781288 Tel: +61-3-90176688 Fax: +86-592-5782298 Fax: +61-3-90176668 Email: sales@clenergy.com.cn Email: sales@clenergy.com.au Website: www.clenergy.com.cn Website: www.clenergy.com.au...
  • Page 11 10 / 12 No. 999-1009, Min’an Avenue, Xiang’an 01/10 Duerdin , Xiamen China 361006 Clayton VIC 3168 Tel: +86-592-5781288 Tel: +61-3-90176688 Fax: +86-592-5782298 Fax: +61-3-90176668 Email: sales@clenergy.com.cn Email: sales@clenergy.com.au Website: www.clenergy.com.cn Website: www.clenergy.com.au...
  • Page 12 Recommended Torque: M8: 18~20Nm 11 / 12 No. 999-1009, Min’an Avenue, Xiang’an 01/10 Duerdin , Xiamen China 361006 Clayton VIC 3168 Tel: +86-592-5781288 Tel: +61-3-90176688 Fax: +86-592-5782298 Fax: +61-3-90176668 Email: sales@clenergy.com.cn Email: sales@clenergy.com.au Website: www.clenergy.com.cn Website: www.clenergy.com.au...
  • Page 13: Warranty

    Clenergy IN WRITING, or if the Product is installed in an environment for which it was not designed. Clenergy shall not be liable for consequential, contingent or incidental damages arising out of the use of the Product by Purchaser under any circumstances.