Location Requirements Between Machine And Building - LAMINOX KING HEAT 6 User Manual

Dc inverter multifunctional air to water heat pump
Table of Contents

Advertisement

The receiving surface of the device must:
- Allow a solid fixation (Preferably concrete).
- Fully support its weight.
- Have a permeable area below the condensate drainage hole (earth, gravel
bed, sand, etc).
- Do not transmit any vibration to the home, recommending the installation of the
anti-vibration dampers supplied with the heat pump.
In case of installing the device on wall mounts, it will be especially important to isolate the
machine from the transmission of vibrations and noise inside the house, it may be
necessary to install more suitable anti-vibration dampers for the wall mount in addition to
those supplied with the heat pump. Nevertheless, the installation on the ground is the most
advisable.
Straighten the heat pump well to ensure that the condensate water cannot exit through
any paths other than the intended drain hole.
Fasten it firmly using 4 sets of M12 bolts suitable for the base material, with nuts and
washers (available on the market). Make sure that the protruding distance of the bolt does
not exceed 10mm inside the metallic support of the device(leg).

4.1-3 Location requirements between machine and building

The heat pump must be installed exclusively outside the home and, where possible, in a
completely clear area. If a protection is needed around the appliance, it should have wide
openings on the 4 sides and the installation separations indicated in the following figure
must be respected. No obstacle should prevent the circulation of air through the
evaporator and the fan outlet.