LAMINOX KING HEAT 6 User Manual page 32

Dc inverter multifunctional air to water heat pump
Table of Contents

Advertisement

P76
EVI EEV manually initial open steps(cooling)
P77
EVI Target superheat (heating)
P78
EVI Target superheat (cooling)
P79
WIFI data upload interval
P80
Reserved
P81
E2 function definition
Starting air temp for second heat source(ambient
P82
temperature ≤-15 ℃, heat pump stops )
DHW circulation pump mode
P83
( C3 pump P88=1 )
Temp Difference For DHW Pump
P84
( C3 pump P88=1 )
P85
Defrost ambient temperature
Defrost ambient temperature and coil
temperature difference ΔT1
P86
(Ambient temperature ≥7 ℃ )
P87
Factory default
P88
C3 pump selection
P89
Suction superheat percentage coefficient
P90
Suction superheat differential coefficient
Defrost ambient temperature and coil
temperature difference ΔT2
P91
(Ambient temperature < 7 ℃ )
Target suction superheat ( Heating ) (Ambient
P92
temperature ≤ -5 )
Target suction superheat ( Heating ) (-5 ≥
P93
Ambient temperature > +5 )
Target suction superheat ( Heating ) (+5 ≥
P94
Ambient temperature > +25)
Target suction superheat ( Cooling )
P95
Target suction superheat ( Heating ) (+45 ≥
P96
Ambient temperature > +25 )
P97
When P40=0, compressor frequency set value
P98
The control signal of G1 valve is reversed
P99
The control signal of G2 valve is reversed
P100
The control signal of G3 valve is reversed
40~480
-5~10 ℃
-5~10 ℃
30~9999 S
0-10 ( display value multiply 0.1)
0-Auxiliary
electrical
heater;
heating source
-30~20°C
0- No; 1- Timer; 2- Temperature; 3-Timer +
Temperature
4~20 ℃
0~20°C
0~20°C
0- No 1-Yes
0- Auxiliary circulation pump
1- DHW circulation pump
0~20
0~20
0~20°C
-20~50°C ( display value multiply 0.1)
-20~50°C ( display value multiply 0.1)
-20~50°C ( display value multiply 0.1)
-20~50°C ( display value multiply 0.1)
-20~50°C ( display value multiply 0.1)
10~100Hz
0 normal / 1 reversed
0 normal / 1 reversed
0 normal / 1 reversed
- 32-
40
40
0
0
0
0
300
300
10
10
1-second
0
0
-15
-15
3
3
5
5
15
15
8
8
0
0
0
0
5
5
1
1
8
8
25
25
25
25
15
15
30
30
5
5
50
50
0
0
0
0
0
0
40
40
0
0
0
0
300
300
10
6
0
0
-15
-15
3
3
5
5
15
15
8
8
0
0
0
0
5
5
1
1
8
8
25
25
25
25
15
15
30
30
5
5
50
50
0
0
0
0
0
0