Error Codes - Elation PROTEUS HYBRID User Manual

Hide thumbs Also See for PROTEUS HYBRID:
Table of Contents

Advertisement

E R R O R C O D E S
When power is applied, the unit will automatically enter a "Reset/Test" mode. This mode brings all
the internal motors to a home position. If there is an internal problem with one or more of the motors
an error code will flash in the display in the form of "XXer" were as XX will represent a function number.
For example, when the display shows "0Er" it means there is some type of error with the Pan motor.
If there are multiple errors during the start-up process, they will all flash in the display. For example: if
the fixtures have errors on Channel 1, 2, and 5 all at the same time, you will see the error message
"01Er", "02Er", and "05Er" flash repeated 5 times.
If an error does occur during the initial start-up procedure the fixture will self-generate a second reset
signal and try to realign all the motors and correct the errors. If the error persists after a second attempt
a third attempt will be made. If after a third attempt all the errors have not been corrected the fixture
will make the following determinations:
• 3 or More Errors - The fixture cannot function properly with three or more errors therefore the
fixture will place itself in a stand-by mode until subsequent repairs can be made.
• Less Than 3 Errors - The fixture has less than 3 errors; therefore, most other functions will work
properly. The fixture will attempt to operate normally until the errors can be correct by a technician.
The errors in question will remain flashing in the display as a reminder of internal errors.
BALLAST ERROR NOTE
IF A BALLAST ERROR MESSAGE APPEARS, TURN THE LAMP OFF FOR 3-5 MINUTES TO
RESET THE BALLAST. IF AFTER 5-MINUTES A BALLAST ERROR STILL APPEARS, TURN THE
FIXTURE OFF TO RESET THE BALLAST. IF A BALLAST MESSAGE STILL APPEARS, PLEASE
CONSULT ELATION CUSTOMER SUPPORT.