Elation PROTEUS HYBRID User Manual page 51

Hide thumbs Also See for PROTEUS HYBRID:
Table of Contents

Advertisement

E R R O R C O D E S
Error Codes are subject to change without any prior written notice.
ERROR CODES
Animation Wheel Er
Dimmer Er
Frost
Wheel Er
Fan Moving
Wheel Er
Array Lens
Wheel Er
1U_FanJB1Fault
1U_FanJB2Fault
3U_FanJB1Fault
3U_FanJB2Fault
4U_FanJB2Fault
5U_FanJB1Fault
6U_FanJB1Fault
7U_FanJB1Fault
7U_FanJB2Fault
DESCRIPTION
The Animation Wheel movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective
motor or a defective motor IC drive on the main PCB). This error may also be
displayed if the head/yoke was blocked during a reset function.
The Dimmer movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure (defective
motor or defective motor IC drive on main PCB). This error may also be displayed if
the head was blocked during a reset function.
The Frost Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or defective motor IC drive on main PCB).
The Fan Moving Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or defective motor IC drive on main PCB).
The Array Lens Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor
failure (defective motor or defective motor IC drive on main PCB).
Error information from JB1 port on 1U01 PCB.
Error information from JB2 port on 1U01 PCB.
Error information from JB1 port on 3U PCB.
Error information from JB2 port on 3U PCB.
Error information from JB2 port on 4U PCB.
Error information from JB1 port on 5U PCB.
Error information from JB1 port on 6U PCB.
Error information from JB1 port on 7U PCB.
Error information from JB2 port on 7U PCB.
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proteus hybrid wmgProteus hybrid fcPrh032

Table of Contents