Troubleshooting
Error
Location
Error
Error
Location
Location
T4EA
Heater A
T4EB
Heater B
32
Type
Description
Type
Type
Description
Description
High Temperature
Switch A
High Temperature
Switch B
Cause
Cause
Cause
Solution
Solution
Solution
Cold ambient
Cold ambient
temperature is
temperature is chilling
causing hose to
the FTS and causing hose
heat
heat to stay on longer
than needed. Insulate
the FTS area of the hose
so that it heats at the
same rate as the rest of
the hose.
Overtemperature
Heater was delivered too
switch sensed a
much power, causing the
fluid temperature
overtemperature switch
above 230°F
to open.
(110°C)
reading properly. After
the heater cools down,
replace RTD. Switch
closes and the error can
be cleared when the
heater temperature falls
below 190°F (87°C).
Disconnected
If heater is not actually
or loose
over temperature,
overtemperature
check all wiring and
switch
connections between
cable/connection
the TCM and the
overtemperature
switches.
Overtemperature
Replace the overtemper-
switch failed in
ature switch.
the open position
Overtemperature
Heater was delivered too
switch sensed a
much power, causing the
fluid temperature
overtemperature switch
above 230°F
to open.
(110°C)
reading properly. After
the heater cools down,
replace RTD. Switch
closes and the error can
be cleared when the
heater temperature falls
below 190°F (87°C).
Disconnected
If heater is not actually
or loose
over temperature,
overtemperature
check all wiring and
switch
connections between
cable/connection
the TCM and the
overtemperature
switches.
Overtemperature
Replace the overtemper-
switch failed in
ature switch.
the open position
RTD is not
RTD is not
334946J