Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
Heater A
T2DA
T2DB
Heater B
T2DH
Hose
334946J
Type
Description
Type
Type
Description
Description
Low Temperature A
Low Temperature B
Low Temperature
Hose
Cause
Cause
Cause
Solution
Solution
Solution
Flow is too
Use a smaller mix
high at current
chamber that is rated
setpoint
for the unit in use. If
recirculating, decrease
flow or decrease
temperature setpoint.
Bad RTD or bad
Swap A and B heater
RTD placement
output cables and RTD
against heater
cables and see if issue
follows. If so, replace
RTD.
Bad heater
Confirm resistance of
element
heater. Heater resistance
should be 9-12 Ω for 10
kW systems and 6-8 Ω
for 15 kW systems. If
out of tolerance, replace
heater element.
Loose heater
Check for loose heater
wires
element wires.
Flow is too
Use a smaller mix
high at current
chamber that is rated
setpoint
for the unit in use. If
recirculating, decrease
flow or decrease
temperature setpoint.
Bad RTD or bad
Swap A and B heater
RTD placement
output cables and RTD
against heater
cables and see if issue
follows. If so, replace
RTD.
Bad heater
Confirm resistance of
element
heater. Heater resistance
should be 9-12 Ω for 10
kW systems and 6-8 Ω
for 15 kW systems. If
out of tolerance, replace
heater element.
Loose heater
Check for loose heater
wires
element wires.
Flow is too
Use a smaller mix
high at current
chamber that is rated
setpoint
for the unit in use. If
recirculating, decrease
flow or decrease
temperature setpoint.
Cold chemical
Recirculate heated
in unheated
chemical back to drum
portion of system
in cold conditions before
passed hose FTS
startup.
at startup
Troubleshooting