Set Thermography Parameters - HIKVISION DS-2TD2636B-15/P User Manual

Thermal & optical bi-spectrum network camera
Table of Contents

Advertisement

Thermal & Optical Bi-spectrum Network Camera User Manual
output alarm if the temperature is higher than the setting value.

3.4.1 Set Thermography Parameters

Configure the basic parameters of temperature screening.
Before You Start
Go to Configuration → System → Maintenance → VCA Resource Type, select Temperature
Screening.
Steps
1. Go to Configuration → Temperature Screening → Basic Settings to configure the parameters.
Enable Temperature Measurement
Check to enable temperature screening function.
Display Temperature Info. on Stream
Check to display temperature information on the stream.
Add Original Data on Capture
Check to add data on alarm triggered capture of thermal channel.
Add Original Data on Stream
Check to add original data on thermal view.
Display Temperature in Alarm Info
Check to add temperature data on alarm pictures.
Data Refresh Interval
It means the refresh interval of temperature information.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range.
Distance
Set the distance between device and the target. You can set Distance Mode as Self-Adaption
or Fixed Distance. In self-adaption mode, the device adjusts the distance between the target
and the device automatically according to the pupil distance. If the distance between the
target and device is fixed, you can select Fixed Distance.
Emissivity
Set the emissivity of your target.
Version
View the version of current algorithm.
2. Click Save.