Set Expert Mode; Set Thermography Rule - HIKVISION DS-2TD6267-100C4L/WY User Manual

Thermal & optical bi-spectrum ptz network camera
Hide thumbs Also See for DS-2TD6267-100C4L/WY:
Table of Contents

Advertisement

Thermal & Optical Bi-spectrum PTZ Network Camera User Manual

3.3.3 Set Expert Mode

Select the temperature measurement rules from Point, Line, or Area and configure parameters,
the device alarms if the alarm rules are met.
Steps
1. Go to Configuration → Temperature Measurement → Basic Settings, check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration → Temperature Measurement → Advanced Settings, select Expert.
4. Refer to Set Preset to set a preset.
5. Select and enable the temperature measurement rules. Please refer to Set Thermography Rule
for setting the rule.
6. Optional: Click Area's Temperature Comparison to set the alarm rules and the temperature.
7. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
8. Click Save.
The maximum temperature and thermography rules will be displayed on the live view.
Note
Go to Image → VCA Rules Display to adjust the fonts size and the temperature colour of
normal, alarm and pre-alarm.
9. Optional: Call the preset and check if the rules are efficient.
10. Enable the scan function of device, such as linear scan to monitor the scene.

3.3.4 Set Thermography Rule

Steps
1. Customize the rule name.
2. Select the rule type to Point, Line, or Area. Then draw a point, line, or area on the interface
where the position to be measured.
Point
Line
Area
3. Configure the temperature measurement parameters.
Emissivity
Set the emissivity of the target. The emissivity of the surface of a material is its effectiveness
in emitting energy as thermal radiation. Different objects have different emissivity. Refer to
Common Material Emissivity Reference to search for the target emissivity..
Please refer to Point Thermographyfor detailed configuration.
Please refer to Line Thermographyfor detailed configuration.
Please refer to Area Thermographyfor detailed configuration.