Urbana U50I-S Installation Manual page 13

Table of Contents

Advertisement

1.
Remove outer screens.
2.
Remove the lower bezel
locate the gas shut-off valve.
3.
Ensure the valve is closed.
OPEN
4.
Next, locate the recessed access plate near
the bottom of the right cabinet side and loosen
the 4 screws using a T20 screwdriver.
and
LOCATION
OF BALL
VALVE
CLOSED
Unpacking and Initial Setup
5.
To remove the plate, lift it up off the key slots
and tilt it inward and out through the opening.
6.
Route the incoming gas line as desired and
connect to the 1/2" NPT female fitting of the
shut-off valve; use gas approved pipe sealant.
Note, the access plate may be left off to allow
for side entry of the incoming gas line.
7.
If use of a regulator is required the square
knockout on the back of the fireplace may be
removed for routing purposes and extra room.
Regulator Knockout
8.
Open shut-off valve and check for
leaks - NEVER USE AN OPEN FLAME!