CLX3300 Series with BHSS Trim
Installation Instructions
Cylinder Installation
7
a
Standard Cylinder (Figure 8)
IMPORTANT
Before installing cylinders:
Use a flat blade screwdriver to rotate cam until the driver points
are in a 6 and 12 o'clock position. (Figure 8A)
Verify that the cylinder spacer is already installed into the shank
on the outside spring housing assembly. Cylinder spacer should be
removed for 7-Pin cylinder.
Note orientation of spacer, if it needs to be reinstalled.
1. Install cylinder into the lever. (Figure 8B)
Cylinder Spacer
b
Interchangeable or Removable Core (Figure 9)
Remove temporary construction core or plastic core. If keyed, use
Control Key. Rotate 15° and pull.
Insert permanent core into lever with control key. Rotate 15° and
remove key.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com •www.corbinrusswin.com
Copyright © 2022, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Figure 8B
Cylinder
Figure 8A
Key
BHSS Trim
Figure 9
3
View into lock from end of trim
12 o'clock drive point
6 o'clock drive point