Cable shield, connected to housing
Fig. 8.2
Pin assignment of plug and KAB139A-6 connection cable
8.3

TEDS transducer identification

TEDS stands for "Transducer Electronic Data Sheet".
An electronic data sheet is stored in the transducer as defined in the IEEE 1451.4
standard, making it possible for the measuring amplifier to be set up automatically. A
suitably equipped amplifier imports the transducer characteristics (electronic data
sheet), translates them into its own settings and measurement can start.
At connection PIN 7 (to ground at PIN 2), there is a digital identification system available.
The basis for this is a 1‐wire EEPROM DS2433, from Maxim/Dallas.
HBM provides you with the TEDS Editor for storing your data. This is included in the
software for the MGCplus Setup Assistant (see TEDS operating manual "TEDS-module in
transducer" on our website at ww.hbm.com/TEDS).
The Editor also makes it possible to manage the different user rights, to protect the
fundamental transducer data from being inadvertently overwritten.
16
WH (white)
Measurement signal (+) U
BK (black)
Excitation voltage (-) U
RD (red)
Measurement signal (-) U
BU (blue)
Excitation voltage (+) U
GN (green)
Sensor circuit (+)
GY (grey)
Sensor circuit (-) (TEDS)
A
(TEDS)
B
A
B