Additional information on the QVD(3.0-6.0:1) Lens
Lens Formula
To calculate the distance between the projector frontside and the screen (PD) for a
given screen width (SW), use the following formula:
Metric system (PD and SW in meter) :
Inch system (PD and SW in inch) :
PD
PD
SW
SW
Lens Cleaning
To minimize the possibility of damaging the optical coating or scratching exposed lens
Procedure
surface, we have developed recommendations for cleaning the lens.
FIRST, we recommend you to try to remove any material from the lens by blowing it off
with clean, dry deionized air. DO NOT use any liquid to clean the lenses.
A Toraysee
Proceed as follows :
Order number for a new Toraysee
Toraysee Cloth
Order Number
BARCO ——————————————————— 4
PD
= 0.048 + 3.010 x SW - 0.039/SW
min
PD
= 0.060 + 6.032 x SW - 0.038/SW
max
PD
=1.89 + 3.01 x SW - 60.45/SW
min
PD
= 2.36 + 6.03 x SW -58.9/SW
max
Minimal projection distance
min :
Maximal projection distance
max :
: 1.2 m
min
: 6 m
max
cloth is included with the lens kit.
TM
Step
Action
1
Always wipe lenses with a CLEAN Toraysee
2
Always wipe lenses in a single direction. Do not wipe back and for-
wards across the lens surface as this tends to grind dirt into the coating.
3
Do not leave cleaning cloth in either an open room or lab coat pocket,
as doing so can contaminate the cloth.
5
If smears occur when cleaning lenses, replace the cloth. Smears are
the first indication of a dirty cloth.
5
Do not use fabric softener when washing the cleaning cloth or softener
sheets when drying the cloth.
6
Do not use liquid cleaners on the cloth as doing so will contaminate the
cloth.
cloth : R379058.