(2) Clean Roller (Set counter for roller
cleaning timing)
(3) Replace Roller (Set counter for roller
replacement timing)
(4) Detect Size
(5) Adjust value for Length manually
(6) Adjust value for Front V. Position manually
(7) Sensor Delay
(Adjust value for Sensor Delay manually)
(8) Adjust value for Front H. Position manually
(9) Adjust value for Back V. Position manually
(10) Adjust value for Back H. Position manually
H. : Horizontal
V. : Vertical
Note:
Execute the Item (5) before the Items (6) and (9).
(From Section 9.6)
7
Select a menu of Setting Item by
pushing "
" or "
Set the parameter by pushing
"
" or "
" key.
Yes
Change
the parameter of another
item?
No
Push HOME key once.
9
(To Section 9.6)
" key.
(2) Set paper scanning numbers
to clean roller
Default; 50,000_
(3) Set paper scanning numbers
to replace roller
Default; 300,000_
(4) A4/Letter
(5)
; 0.1 % longer
; 0.1 % shorter
(6)
; 0.1mm to lower side
; 0.1mm to upper side
(7) 80-255
; 0.1msec longer delay-time
; 0.1msec shorter delay-time
(8)
; 0.1mm to the right
; 0.1mm to the left
(9) Same as (6)