Advertisement

Quick Links

All manuals and user guides at all-guides.com
4 Le Pas du Château
85670 SAINT PAUL MONT PENIT
TEL : +33 (0)2 51 98 55 64
FAX : +33 (0)2 51 98 59 07
Email :
info@medicatlantic.fr
Site Internet : https://www.winncare.fr
USER MANUAL
MEDICAL BED KALIN (PO3P+OPTION)
580049 Anglais
Creation 2014_01_01
Update 2021_07_08
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KALIN PO3P OPTION and is the answer not in the manual?

Questions and answers

Summary of Contents for Winncare KALIN PO3P OPTION

  • Page 1 85670 SAINT PAUL MONT PENIT TEL : +33 (0)2 51 98 55 64 FAX : +33 (0)2 51 98 59 07 Email : info@medicatlantic.fr Site Internet : https://www.winncare.fr USER MANUAL MEDICAL BED KALIN (PO3P+OPTION) 580049 Anglais Creation 2014_01_01 Update 2021_07_08...
  • Page 2: Table Of Contents

    All manuals and user guides at all-guides.com 1. TRANSPORT AND STORAGE 2. BED ENVIRONMENT CONDITIONS 3. GENERAL USE 3.1. P REREQUISITES BEFORE USE AND INSTRUCTIONS FOR USE 3.1.1. T RAINING AND QUALIFICATIONS OF THE PERSON USING THE DEVICE 3.1.2. I NDICATIONS 3.1.3.
  • Page 3 All manuals and user guides at all-guides.com 8.2. W OODEN BARRIERS 8.2.1. I NSTALLATION OF THE BARRIER 8.2.2. U SE OF THE BARRIER 8.2.3. W A551-00 ALL STOP 8.3. A NGLED LIFTING POLE AND STAND 8.3.1. P OSITIONING OF THE STEM AND THE POLE ON THE BED BASE 8.3.2.
  • Page 4: Transport And Storage

    All manuals and user guides at all-guides.com Dear Sir/Madam, You have acquired a WINNCARE medical bed equipped with its accessories, and we thank you for your custom. This class 1 medical device complies with Regulation (EU) 2017/745 relating to medical devices...
  • Page 5: Indications

    All manuals and user guides at all-guides.com The user and staff must be trained and aware of the risks associated with using the bed. He must not allow it by children and be vigilant when used by confused or disoriented people. 3.1.2.
  • Page 6 In the case of the use of infrared remote control(s), WINNCARE allows the establishment of a single bed in the same room (or in a close environment) or a second bed only if the infrared options of 2 beds concerned are different (I and I1).
  • Page 7: Electrical Characteristics

    All manuals and user guides at all-guides.com Brake the wheels. The mains socket should remain accessible to enable the bed to be disconnected quickly. Plug in the power lead, checking that the mains comply with the standards in force and that it is suitable for the supply box voltage.
  • Page 8: Electromagnetic Compatibility

    All manuals and user guides at all-guides.com 3.4.2. Electromagnetic compatibility The bed is an electromedical device requiring special precautions with regard to electromagnetic compatibility. The device must be installed and put into service according to the EMC information provided in this manual. The use of accessories, transducers, and cables other than those specified or supplied by the manufacturer may cause increased electromagnetic emissions or a decrease in the immunity of the device and may cause improper operation.
  • Page 9: Equipotentiality

    All manuals and user guides at all-guides.com Test specification for immunity to RF wireless communications devices Test frequency (MHz) Modulation Immunity test level (V/m) Pulse Modulation : 18 Hz FM + 5 Hz deviation : 1 kHz sine 710 – 745 – 780 Pulse Modulation : 217 Hz 810 –...
  • Page 10: Bed Boards 80Cm Width Compatible

    Kit for side loading bed S0200 Stainless steel intravenous stand on base Y0300 Lifting pole on U shaped base, fixed height 23.3 Only accessories and boards supplied by WINNCARE guarantee you a compatibility with our products Incompatible accessories and boards can pose RISKS...
  • Page 11: Use

    All manuals and user guides at all-guides.com 6. USE 6.1. Purpose of medical device ➢ The device is intended to compensate for a handicap and as a preventive measure. ➢ These beds are intended : -Application environments 3 (Senior care centres if adult person with atypical anatomy), 4 and 5 (Home care and in-facility when equipped with the emergency CPR back-rest release option).
  • Page 12: General Description

    Foot board Head board Slatted folding leg lift Base and cross pieces Gallows Wheels housings (corner) Intravenous holder rod housing 6.4. Technical characteristics 6.4.1. Dimensional 42° Ø10 cm 12 cm WINNCARE recommend the use of the XS 150 patient lift.
  • Page 13: Bed Weight

    All manuals and user guides at all-guides.com 626 mm 240 mm 470 mm 637 mm 637 mm 6.4.2. Bed weight TOTAL Bed with electric knee break leg lift 70 kg (without boards) 6.4.3. Noise The measurement of the maximum audible sound power in accordance with ISO 3746 is 45.2 dB(A). 6.4.4.
  • Page 14: Protection Level Against Dust And Liquid Penetration

    All manuals and user guides at all-guides.com 6.4.5. Protection level against dust and liquid penetration number (decade) number (unit) Index Protection against solids Protection against water intrusion No protection. No protection. Protected against solid bodies greater than Protected against vertical drops of water drops. 50 mm.
  • Page 15: Remote Control

    All manuals and user guides at all-guides.com 6.6. Remote control The remote control and its cable are protected in a lockable box when the functions of the bed are not modified. This arrangement avoids any risk of involuntary activation and suffocation. LOCATION OF THE REMOTE CONTROL ON THE BED...
  • Page 16 All manuals and user guides at all-guides.com Carry out a test cycle when the bed is empty to familiarise yourself with the bed functions. Lifting and lowering of back rest Lifting and lowering of variable height Lifting and lowering of electric folding Simultaneous lifting and lowering of back rest and folding...
  • Page 17: Braking

    All manuals and user guides at all-guides.com KEY TO LOCK A KEY IN VERTICAL TURN THE KEY SLIGHTLY TO FUNCTION POSITION: THE THE RIGHT TO LOCK THE FUNCTION IS FUNCTION UNLOCKED 6.7. Braking 6.7.1. Separate braking Check that the wheels are locked by trying to move the bed. If this is not done, the patient or another person who leans on the bed may fall.
  • Page 18: Centralized Braking

    All manuals and user guides at all-guides.com 6.7.2. Centralized braking Braked wheels: press pedal (red side) with the foot. Freewheels: Press pedal (A or C) with the foot to get the middle position. C. Directional Wheel: Press pedal (green side) with the foot 7.
  • Page 19: If The Bed Is Fitted With An Emergency Release For The Back Rest (Cardio Pulmonary Resuscitation)

    All manuals and user guides at all-guides.com Version with handle on the back rest Version without handle on the back rest 7.1.2. If the bed is fitted with an emergency release for the back rest (Cardio Pulmonary Resuscitation) 1) Grasp the back rest with one hand. 2) With the other hand, activate one of the two handles on the back rest while lowering.
  • Page 20: Installation Of Accessories

    All manuals and user guides at all-guides.com 8. INSTALLATION OF ACCESSORIES 8.1. Boards ➢ Installing a bed board : ➢ Removing a bed board : Assemble the highest board on the head side.
  • Page 21 8.2. Wooden barriers INCOMPATIBLE SIDE BARRIERS CAN CAUSE HAZARDS. The wooden barriers are designed to be used on WINNCARE beds with a length of 1700 mm, with panels provided with the necessary reservations for their installation. The barrier was tested in accordance with the test method of the park bed standard NF EN 50637 :2017.
  • Page 22 All manuals and user guides at all-guides.com The element composed of the wood and metal bar is always placed in the lower part. The arrow down and to the inside of the bed...
  • Page 23 All manuals and user guides at all-guides.com...
  • Page 24 All manuals and user guides at all-guides.com 8.2.2. Use of the barrier ➢ To lower the side rail : Take the upper bar and lift it up to its locking at the top of the panel. Check if it is properly engaged.
  • Page 25 All manuals and user guides at all-guides.com ➢ To lower the side rail: 1) l Lift the upper bar 2) Press the locking buttons of each panel.
  • Page 26 All manuals and user guides at all-guides.com 1) Slide the barrier gently down the bed (make sure that no objects or parts of the patient's body or nursing staff are in the operating area) until the stop is stopped . The upper bar comes to rest on the lower metal / wood bar assembly.
  • Page 27 All manuals and user guides at all-guides.com 8.3. Angled lifting pole and IV stand 8.3.1. Positioning of the stem and the IV pole on the bed base 8.3.2. Specific features of the jib crane and lifting handle The A681-00 Stem has been sized for junior beds and complies with STANDARD EN 50637...
  • Page 28 All manuals and user guides at all-guides.com 9. MAINTENANCE No maintenance should be done in the presence of a patient on the bed. 9.1. Identification Warning Manufacturer's address and Medical device) contact details Complies with regulations (EU) Product reference and name Read the instruction manual Product serial number YY : Year of manufacture...
  • Page 29 All manuals and user guides at all-guides.com 9.3. Maintenance Quality control of medical beds and its accessories will be made by technical staff or trained biomedical and taking into account the normal conditions of use specified in the user guide. The bed must be available to perform all quality control at least once a year, but also on special request and corrective maintenance on the performance that could be affected by the intervention.
  • Page 30 All manuals and user guides at all-guides.com 9.4. Quality inspection of medical beds ANNUAL MAINTENANCE OF MEDICAL BEDS IDENTIFICATION ESTABLISHMENT Type model / Trademark : Date of manufacture : Serial or park number : Application Environment Congruent Improper VISUAL CONTROL applicable Identification - label General cleanliness...
  • Page 31 All manuals and user guides at all-guides.com 9.5. Cleaning and disinfection High pressure cleaning, machine cleaning, washing tunnel or jet cleaning is prohibited. Unplug the mains lead. Check that all the electrical parts are connected together. All the sockets of the supply box must be used or filled, otherwise its watertightness is not guaranteed.
  • Page 32 All manuals and user guides at all-guides.com Do not rinse or wipe. Check the operation of all the bed functions Repair if necessary Pack in thermoplastic film Warning In the event of additional precautions (Contact precautions, Droplets or Air), apply the measures recommended by the hospital hygiene department The use of a Javel water solution of more than 5000ppm (0.5% of active chlorine) should be justified by a microbiological risk and only applied for the required time (Risk of ageing of some materials,...
  • Page 33 All manuals and user guides at all-guides.com 9.8. Troubleshooting Guide DEFAULT POSSIBLE CASE HELP The whole bed is not working The bed is not electrically powered Check the electrical connection (Green power LED on controlbox) The remote control is fully locked Unlock the remote control The infrared remote control is not powered or is not Remove the rear cover...
  • Page 34 Environment Department of Winncare at n ° +33 (0)2.51.98.55.64 Winncare also encourages you to limit the possible effects of waste on the environment and public health in all other countries, by complying with local selective sorting laws, separating waste from Electrical and Electronic...
  • Page 35 All manuals and user guides at all-guides.com...
  • Page 36 All manuals and user guides at all-guides.com...