Function
- Oil burner pump
DANFOSS 
BFP 11 R3
Y1
3
5
1
2
Without horse-shoe
-shaped washer.
1
2
1
One-pipe system
With horse-shoe
-shaped washer.
4
2
3
1
420010029304
1
suction intake connection.
2
return connection.
3
pressure connection.
4
oil pressure gauge connection.
10
5
negative pressure gauge connection.
6
oil pressure regulator.
10
Solenoid valve electrical connection.
4
Y1
fuel-oil solenoid valve.
6
1
Hoses
2
Filter
3
Oil cock
4
Plug
3
ONE PIPE SYSTEM: If the oil supply
circuit is one-pipe system, the pump
needs to be modified following intructions
in the picture.
The oil burner pump used is a self-priming
gear pump, which must be connected as
two-line pump via a bleed filter. There is an
intake filter and an oil pressure regulator
integrated in the pump. Pressure gauges
for pressure measurements and negative
pressure measurements must be
connected before the equipment is
commissioned.
NB: before starting the burner, check that
the return pipe is open. An eventual
obstraction could damage the pump
sealing device.