Installation
Mounting Angle
·
Incline the Head by 15° and mount the Head so that no regular reflection light affects the Sensor.
·
Use the provided Mounting Bracket to mount the Head.
F10-S30R: 100±10 mm
F10-S15R: 50±5 mm
F10-S05R: 33±3 mm
Note:
Position the sensor perpendicular to the direction of motion of the target object.
Connection with Peripherals (F10-C50/C55 Only)
You can input the measurement trigger and output the measurement results via an RS-232C port. You can also back up the settings in an IBM
PC/AT or compatible. Refer to the Operation Manual for the Unit for details on communications commands.
1:1 Connection
16
Downloaded from
Elcodis.com
electronic components distributor
F10-S30R
F10-S15R
F10-S05R
15°
Line direction
Use F10 products for items marked with an asterisk.

*F10-VR2

RS-232C Cable
F10-C50/C55
Simulation
System configuration
Sensor direction
15° 15°
Production
line direction
IBM PC/AT or
compatible
F10