Download Print this page

Omron F10 Manual page 18

Pattern matching sensor
Hide thumbs Also See for F10:

Advertisement

F10
Buzzer
sounds
Control output (OUTPUT) and enable
output are OFF, and will not turn ON.
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Amplifiers
F10-Cj
Downloaded from
Elcodis.com
electronic components distributor
Problem
Serial buffer overflow error
8
Either the send buffer or receive buffer has
7
become full during communications.
6
5
4
This LED of the threshold
indicators flashes and the
3
buzzer sounds three
2
times.
1
A current exceeding the rated value has
flowed to the output transistor and the
overcurrent protective circuit has been
triggered.
5.7-dia. 11-core vinyl-insulated round cable, standard length: 2 m
(Conductor cross-section: 0.2 mm
Mounting Dimensions
Probable cause
2
, insulator diameter: f 1.0 mm).
Remedy
Send buffer overflow
Change the communications settings.
Receive buffer overflow
Wait for a response from the F10, then
send the command.
Reduce the current so that it will not
exceed the rated value.
Note: If the output does not turn ON even
after reducing the current below the rated
value, contact your OMRON
representative.
F10-C50/C55 only
2-M4
F10
25

Advertisement

loading