3. Performing Measurement in Response to External Input Signals (RUN Mode)
(1) Set the mode selector to RUN.
When the switch is set to RUN mode, measurements are made in response to external input signals.
Relationship between the F10 I/O terminal operations and ON/OFF indications in the timing charts are as shown in the following table.
Input
TRIG (pink)
CONT (white)
S_TEACH (yellow)
S_TEACH (yellow)
M_TEACH (purple)
M_TEACH (purple)
BANK1 (gray) (see note)
BANK2 (green) (see note)
BANK3 (red) (see note)
Output
OUTPUT (black)
OUTPUT (black)
ENAB (orange)
Note:
F10-C20/C25 do not have banks 1 to 3.
CONT Mode
In CONT mode, the Sensor is in sensing operation repeatedly while
the CONT signal is ON. The measurement result is renewed once
per measurement cycle, and output.
TRIG Mode
The Sensor in TRIG mode is used for object measurement only
once in synchronization with the rising edge of the TRIG signal and
the result is output.
Normal mode
Wide mode (plain measurement)
Minimum ON width for the trigger signal is 1 ms.
The OUTPUT signal is stored until the measure-
ment results are refreshed.
ENAB signal:
OFF width is 10 ms in normal mode.
Turns ON when the OUTPUT signal is re-
freshed.
22
Downloaded from
Elcodis.com
electronic components distributor
Signal
Indication in timing charts
ON
OFF
ON
OFF
TRIG
OUTPUT
3.6 ms max.
ENAB
OUTPUT
3.6 ms max.
ENAB
Measurement cycle: Tout
NPN (F10-C20/C30/C50)
GND
OPEN
GND
Vcc
Measurement cycle: Tout
Normal mode: 3.6 ms
Wide mode: 10.8 ms
Plain measurement: 7.2 ms
POINT
Turning the Guide Light ON and OFF:
In RUN mode, even when synchronous measurement
is not being executed, the guide light will normally be
ON. It is possible to turn the guide light OFF (and ON
again) by pressing the UP selection button as required.
While the guide light is being turned ON or OFF, the
ENAB signal is turned OFF, and no external inputs can
be received.
The OUTPUT signal is turned OFF when the UP selec-
tion button is pressed.
Press and hold
down the UP
selection button.
OUTPUT
ENAB
Guide light
ON: Lit
OFF: Unlit
Normal mode: 7.2 ms max.
Wide mode: 14.4 ms max.
Plain measurement: 10.8 ms max.
F10
PNP (F10-C25/C35/C55)
Vcc
OPEN
Vcc
GND
0.7 s max.