Omron F10 Manual page 14

Pattern matching sensor
Hide thumbs Also See for F10:

Advertisement

F10
Plain Measurement
Press the teach/display button to change the display (DEV-AVE).
·
·
Bank No.
(2) Press the UP/DOWN selection buttons to adjust the threshold.
Adjust the threshold to the most suitable level by monitoring the level indicator.
Altered threshold values will not be saved unless the mode selector is changed once to either RUN or TEACH.
Pattern Measurement
In wide mode, the pattern with the lowest degree of conformance among the three models is selected.
Plain Measurement
Set the threshold values for both DEV (deviation level) and AVE (average density). If either is lower than the threshold value, the discrimi-
nation result will be set to OFF.
Note:
Use the DIP switch to turn ON and OFF the output signal. Refer to Nomenclature for details.
Downloaded from
Elcodis.com
electronic components distributor
Status indicators (F10-C20/C25)
Plain measurement
Status indicator (F10-C30/C35/C50/C55)
Press the teach/
display button
Displays the
mode indicating
the current level.
Closer to model
in appearance
Turns ON if the measurement value
is higher than the threshold.
The result indicator and output
signal are ON. (See note.)
PATT
Deviation level
Difference from average
density during teaching
Plain measurement
DEV (deviation level)
Returns to bank number
display if no operation is
performed for 5 seconds.
Returns to bank number
display if no operation is
performed for 5 seconds.
Plain measurement
AVE (difference from taught
average density)
Threshold value
Not closer to model
in appearance
Turns OFF if the measurement
value is lower than the threshold.
The result indicator and output
signal are OFF. (See note.)
Deviation
level is
small
Deviation
level is
Increases the smaller
great
the deviation level.
Difference from
Press the
registered pattern
Display
is small
Button
Average density
Difference from
registered pattern
is great
Increases the smaller the
deviation level compared
with the taught average
density.
Threshold value
F10
DEV lit
AVE lit
21