Download Print this page

Settings Menu; Wireless Lite Thermostats - Daikin Airzone DZK-4 User Manual

Zoning kit

Advertisement

Available languages

Available languages

User's manual

Settings Menu

Local Ventilation. This option enables the activation
selected zone when the system is not actively cooling or heating any of the zones.
Important: In Heat Pump installations, it is recommended not to activate the global and local ventilation in
a DZK system connected to the master indoor unit. It may cause the Stop user mode to turn off the rest of
the DZK system.
Timer. It is an auto power-off timer of the zone:
Off. Timer is not activated.
30. Thirty minutes after its activation, the zone will turn off.
60. Sixty minutes after its activation, the zone will turn off.
90. Ninety minutes after its activation, the zone will turn off.
Information. This parameter provides information on:
Zone: firmware, zone, association, actuator or status of the communications.
System: firmware, settings and information about the system controllers.
Devices: It displays the elements connected to the system.
Zone navigation. This parameter is only available when there is an error with the master wired thermostat.
Access and modify the set-point temperature, mode, user mode and flow rate parameters via the "all
zones" option.

WIRELESS LITE THERMOSTATS

On/Off
Lower
temperature
Important: After 10 seconds of inactivity, the wireless Lite thermostat will turn off all its LEDs to save battery
power. A first press on
press you can change the desired parameter (On/Off or temperature).
shows the zone status (On/Off, operation mode and temperature). After this first
or deactivation
of the ventilation in the
Raise
temperature
EN
13

Advertisement

loading